Skip to main content
Schneider Electric EZC100H2025 — Circuit Breaker Accessories

Schneider Electric EZC100H2025 EasyPact EZC100H, 25 A, 2-Pol

MPNEZC100H2025
Active

Schneider Electric EasyPact EZC100H, EZC100H2025, 2-pole thermal-magnetic circuit breaker, 25 A rated current, breaking capacity 10-100 kA AC/DC, IEC 60947-2.

$52.89Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC100H2025 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100H2025 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]25 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description2P
EZC100H2025 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating25 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100H2025 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width50 mm
Height130 mm
Depth60 mm
EZC100H2025 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100H2025 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2

Product details

The EZC100H2025 is a 2-pole thermal-magnetic circuit breaker from the Schneider Electric EasyPact EZC100H range, rated 25 A at 40 °C (25 A at 50 °C with the TM-D trip unit). The 25 A continuous rating sets the maximum load current before the thermal element begins to trip — sized for a 25 A feeder or branch circuit on a distribution panel. The magnetic (short-circuit) element reacts to instantaneous overcurrents, with breaking capacity (Icu) ranging from 10 kA at 125 V DC / 550 V AC up to 100 kA at 110–130 V AC, all per IEC 60947-2. At 400–415 V AC the Icu is 30 kA; at 440 V AC it's 20 kA. For DC circuits, 10 kA at 125 V DC (1-pole) or 250 V DC (2-pole).

Deployment context

Mounts fixed to a backplate (not DIN rail) with front-front connections — both line and load terminate on the front face, which simplifies busbar and cable routing in a distribution board. The IP20 finger-safe enclosure suits dry indoor panels; the IK07 impact rating means it withstands accidental tool drops during panel assembly.

Certified to GB/T 14048.2, EN/IEC 60947-1, JIS C8201-2-2, and EN/IEC 60947-2 — covering China, Europe, Japan, and the international IEC standard. No earth-leakage protection built in; if ground-fault protection is needed, an external RCD or earth-leakage module must be added.

Frequently asked questions

Where can I buy EZC100H2025 and how do I get a price?

The EZC100H2025 is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the breaking capacity of EZC100H2025 at 400 V AC?

At 400–415 V AC 50/60 Hz, the breaking capacity (Icu) is 30 kA per IEC 60947-2.

What compliance documentation does Schneider provide for EZC100H2025?

The breaker is certified to GB/T 14048.2, EN/IEC 60947-1, JIS C8201-2-2, and EN/IEC 60947-2. It is suitable for isolation per IEC 60947-2. No earth-leakage protection is included.

MPN