Schneider Electric EZC100H2080 — Circuit Breaker Accessories

Schneider Electric EZC100H2080 EasyPact EZC100H 80A 2P Circu

MPNEZC100H2080
Active

Schneider Electric EasyPact EZC100H, 2-pole thermal-magnetic circuit breaker, 80 A rated current, 10-100 kA breaking capacity, toggle control, front connection.

$52.89Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100H2080 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100H2080 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]80 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description2P

Protection & Performance

EZC100H2080 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating80 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100H2080 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width50 mm
Height130 mm
Depth60 mm

Environmental

EZC100H2080 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100H2080 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2

Product details

The Schneider Electric EZC100H2080 is a 2-pole thermal-magnetic circuit breaker from the EasyPact EZC100H series, rated 80 A at 40 °C (80 A at 50 °C with the TM-D trip unit). It's built for distribution duty — Category A utilization, meaning it's not intended for frequent switching under load but for branch-circuit protection where the load is switched elsewhere. Breaking capacity varies by voltage: 100 kA Icu at 110–130 V AC, 50 kA at 220–240 V AC, 30 kA at 380–415 V AC, 20 kA at 440 V AC, 10 kA at 550 V AC, and 10 kA at 125 V DC (1P) or 250 V DC (2P). That H breaking-capacity code means it handles high fault currents on the low-voltage side of a transformer or near a large service entrance.

Fixed mounting on a backplate — no DIN rail adapter on this one. Front connections top and bottom, with a 25 mm connection pitch. Dimensions: 130 mm high, 50 mm wide, 60 mm deep. IP20 finger-safe terminals, IK07 impact resistance. Mechanical durability is 13,000 cycles — fine for a panel main or feeder breaker that sees infrequent operation.

Frequently asked questions

Where can I buy EZC100H2080?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of EZC100H2080?

Breaking capacity is 100 kA Icu at 110–130 V AC, 50 kA at 220–240 V AC, 30 kA at 380–415 V AC, 20 kA at 440 V AC, 10 kA at 550 V AC, and 10 kA at 125 V DC (1P) or 250 V DC (2P), all per IEC 60947-2.

What compliance documentation does Schneider provide for EZC100H2080?

The breaker is designed to EN/IEC 60947-1, EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It carries IP20 protection and IK07 impact rating. Specific RoHS/REACH/UL declarations are available from the manufacturer upon request.