Schneider Electric EasyPact EZC100H series, EZC100H3016, 3-pole molded-case circuit breaker, 16 A thermal-magnetic TM-D trip unit, breaking capacity code H, fixed mount, toggle control.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100H3016 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100H3016 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]16 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P

Protection & Performance

EZC100H3016 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating16 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100H3016 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm

Environmental

EZC100H3016 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100H3016 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-1 EN/IEC 60947-2 JIS C8201-2-2

Product details

The EZC100H3016 is a 3-pole molded-case circuit breaker from the EasyPact EZC100H range, rated 16 A at 40 °C (trip unit TM-D, thermal-magnetic). The 'H' breaking capacity code delivers 100 kA Icu at 110–130 V AC, 50 kA at 220–240 V AC, 30 kA at 380–415 V AC, 20 kA at 440 V AC, and 10 kA at 550 V AC — all per IEC 60947-2. On the DC side it holds 10 kA at 125 V DC (1P) or 250 V DC (2P). No earth-leakage protection built in — if you need GFCI, add an external Vigi module.

Fixed backplate mount, front connections both line and load sides. Dimensions: 130 mm high, 75 mm wide, 60 mm deep — fits a standard 3-pole MCCB footprint with 25 mm connection pitch. IP20 finger-safe on the front; IK07 impact resistance means it survives a moderate tool drop during installation.

Current-production part — no end-of-life notice. The EasyPact EZC100H series is Schneider's economy molded-case breaker line for distribution duty.

Frequently asked questions

What are the key ratings of the EZC100H3016?

16 A rated current at 40 °C, thermal-magnetic TM-D trip unit, 3 poles, breaking capacity up to 100 kA Icu at 240 V AC and 30 kA at 400 V AC per IEC 60947-2. No earth-leakage protection built in.

What compliance documentation does Schneider provide for EZC100H3016?

The breaker is certified to GB/T 14048.2, EN/IEC 60947-1, EN/IEC 60947-2, and JIS C8201-2-2. It carries IP20 protection, IK07 impact rating, and is suitable for isolation per IEC 60947-2. Specific RoHS/REACH declarations are available from Schneider's product documentation portal.

MPN