Schneider Electric EZC100H3075 — Circuit Breaker Accessories

EZC100H3075 EasyPact EZC100H 75A 3P MCCB, 10-100kA Icu

MPNEZC100H3075
Active

Schneider Electric EasyPact EZC100H, EZC100H3075, 3-pole 75 A thermal-magnetic MCCB, 10-100 kA Icu breaking capacity, IP20, backplate mount.

$58.77Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100H3075 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100H3075 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]75 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P

Protection & Performance

EZC100H3075 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating75 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100H3075 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm

Environmental

EZC100H3075 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100H3075 — Approvals
ParameterValue
StandardsGB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-2 EN/IEC 60947-1

Product details

The Schneider Electric EZC100H3075 is a 3-pole EasyPact EZC100H molded case circuit breaker rated at 75 A (In) at 40 °C, with a TM-D thermal-magnetic trip unit. It carries a 10 kA Icu at 125 V DC (1P) and 250 V DC (2P), and on AC it delivers 100 kA Icu at 110-130 V / 220-240 V, 30 kA at 380-415 V, 20 kA at 440 V, and 10 kA at 550 V — all per IEC 60947-2. That's a wide fault-clearing envelope that covers most industrial distribution panels fed from a transformer of 500 kVA or less.

What the breaking capacity means on your line

The 30 kA at 400-415 V is the more common ceiling for European 400 V distribution. At 440 V it drops to 20 kA, still enough for most downstream feeders. On the DC side, 10 kA at 250 V (2P) covers battery banks and UPS outputs. The Category A utilization rating means this breaker is not intended for motor starting duty — it's a distribution breaker, not a motor circuit protector.

Backplate-mounted, fixed position. Front-facing connections top and bottom with a 25 mm connection pitch — standard for panel builder bus bar work. The toggle handle gives positive contact indication, so you can see the contact state at a glance. IP20 finger-safe protection on the front; IK07 impact rating means it'll survive a dropped tool in the panel.

Designed and tested to GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-2, and EN/IEC 60947-1. No earth-leakage protection built in; if you need RCD functionality, you add an external Vigi module upstream.

Frequently asked questions

What is the breaking capacity of the EZC100H3075 at 400 V AC?

At 400-415 V AC 50/60 Hz, the EZC100H3075 delivers 30 kA Icu per IEC 60947-2. At 440 V it drops to 20 kA, and at 550 V to 10 kA.

What is the closest alternative to the EZC100H3075 in the same family?

Within the EasyPact EZC100H range, the closest peer is the EZC100H with a different trip rating — for example, the 100 A variant (EZC100H3100) shares the same frame, breaking capacity, and mounting footprint. The only difference is the TM-D trip unit setting. If you need a higher interrupting rating at 400 V (50 kA instead of 30 kA), you step up to the EasyPact EZC250H or the Compact NSX160.

Where can I buy the EZC100H3075?

This part is sourced through independent industrial distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at the time of quotation — no blanket stock count is maintained online.

What compliance documentation does Schneider provide for the EZC100H3075?

The breaker carries compliance with GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-2, and EN/IEC 60947-1. It is suitable for isolation per IEC 60947-2. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration of compliance with your RFQ.

MPN
EZC100H3075