Skip to main content
Schneider Electric EZC100H3075

EZC100H3075 EasyPact EZC100H 75A 3P MCCB, 10-100kA Icu

MPN EZC100H3075
Active

Schneider Electric EasyPact EZC100H, EZC100H3075, 3-pole 75 A thermal-magnetic MCCB, 10-100 kA Icu breaking capacity, IP20, backplate mount.

$58.77 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H3075 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC100H3075 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width75 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100H3075 is a 3-pole EasyPact EZC100H molded case circuit breaker rated at 75 A (In) at 40 °C, with a TM-D thermal-magnetic trip unit. It carries a 10 kA Icu at 125 V DC (1P) and 250 V DC (2P), and on AC it delivers 100 kA Icu at 110-130 V / 220-240 V, 30 kA at 380-415 V, 20 kA at 440 V, and 10 kA at 550 V — all per IEC 60947-2. That's a wide fault-clearing envelope that covers most industrial distribution panels fed from a transformer of 500 kVA or less.

What the breaking capacity means on your line

The 30 kA at 400-415 V is the more common ceiling for European 400 V distribution. At 440 V it drops to 20 kA, still enough for most downstream feeders. On the DC side, 10 kA at 250 V (2P) covers battery banks and UPS outputs. The Category A utilization rating means this breaker is not intended for motor starting duty — it's a distribution breaker, not a motor circuit protector.

Backplate-mounted, fixed position. Front-facing connections top and bottom with a 25 mm connection pitch — standard for panel builder bus bar work. The toggle handle gives positive contact indication, so you can see the contact state at a glance. IP20 finger-safe protection on the front; IK07 impact rating means it'll survive a dropped tool in the panel.

Designed and tested to GB/T 14048.2, JIS C8201-2-2, EN/IEC 60947-2, and EN/IEC 60947-1. No earth-leakage protection built in; if you need RCD functionality, you add an external Vigi module upstream.

MPN
EZC100H3075