Skip to main content
Schneider Electric EZC100H3100 — Circuit Breaker Accessories

Schneider EZC100H3100 EasyPact EZC100H Circuit Breaker, 100

MPNEZC100H3100
Active

Schneider Electric EasyPact EZC100H series, EZC100H3100, 3-pole thermal-magnetic circuit breaker, 100 A rated current, 10–100 kA breaking capacity, toggle control, IP20, backplate mount.

$58.77Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100H3100 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100H3100 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]100 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P

Protection & Performance

EZC100H3100 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating100 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100H3100 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm

Environmental

EZC100H3100 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100H3100 — Approvals
ParameterValue
StandardsGB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-1 EN/IEC 60947-2

Product details

The EZC100H3100 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC100H family, rated 100 A at 40 °C ambient (100 A at 50 °C with the TM-D trip unit). No earth-leakage protection is built in — if you need that, add a separate RCD or specify the EZC with a Vigi module. Breaking capacity varies by voltage: 100 kA Icu at 240 V AC, 30 kA at 400 V AC, 10 kA at 550 V AC, and 10 kA at 250 V DC (2-pole series). The 'H' in EZC100H means the high-breaking version — it clears faults up to 100 kA at the lower voltages, which covers most distribution panels fed from a transformer. For DC circuits, the 10 kA at 125 V DC (1-pole) or 250 V DC (2-pole) is adequate for industrial control power supplies. Mounting is fixed to a backplate — no DIN-rail adapter in this variant. The front connection (both line and load) keeps wiring accessible when the breaker is panel-mounted. IP20 finger-safe terminals;

Also carries GB/T 14048.2 (China) and JIS C8201-2-2 (Japan) — so it's accepted in panels destined for Asia-Pacific markets. The toggle handle gives positive contact indication (you see the position). Mechanical durability is 13,000 cycles — that's the number of on-off operations before wear-out. For a distribution breaker that cycles a few times a year, that's decades of service. Electrical endurance depends on the load current and voltage; for motor-starting duty, derate the cycle count.

Frequently asked questions

What compliance documentation is available for EZC100H3100?

The breaker is certified to EN/IEC 60947-1 and 60947-2, GB/T 14048.2, and JIS C8201-2-2. RoHS and REACH compliance is standard for Schneider EasyPact products, though the specific declarations are not in this evidence set.

MPN
EZC100H3100