Skip to main content
Schneider Electric EZC100H4032

Schneider Electric EZC100H4032 EasyPact EZC100H, 32 A, 4P, 1

MPN EZC100H4032
Active

Schneider Electric EasyPact EZC100H series, EZC100H4032, 4-pole molded case circuit breaker, 32 A, thermal-magnetic TM-D trip unit, breaking capacity code H, 10-100 kA Icu.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100H4032 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC100H4032 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width100 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100H4032 is a 4-pole molded case circuit breaker from the EasyPact EZC100H range, rated 32 A at 40 °C with a thermal-magnetic TM-D trip unit. The 'H' breaking capacity code means it delivers 100 kA Icu at 110-130 V AC, 50 kA at 220-240 V AC, 30 kA at 380-400 V AC, and 20 kA at 440 V AC — figures that govern its use in high-fault distribution panels where SCCR coordination is critical. At 125 V DC (1P) and 250 V DC (2P) it still holds 10 kA Icu, so it handles DC bus applications in the same footprint. The 32 A rating at 50 °C on the trip unit means you get the full 32 A continuous without derating up to that ambient — above that, the thermal element starts to shift. Mounting is fixed backplate, not DIN rail — plan for a dedicated cutout or enclosure backplate. Front connections both top and bottom simplify bus-bar routing in a distribution board. The 25 mm connection pitch matches standard MCCB terminal spacing for lug or fork terminals.

The EZC100H4032 is certified to EN/IEC 60947-2 (the main MCCB standard for industrial applications), EN/IEC 60947-1 (general rules), plus GB/T 14048.2 (China) and JIS C8201-2-2 (Japan). IP20 finger protection on the front face, IK07 impact resistance per EN 50102. Storage temperature range -35 to 85 °C, operating -25 to 70 °C — wide enough for unheated warehouses or outdoor enclosures in temperate climates.

MPN
EZC100H4032