Skip to main content
Schneider Electric EZC100H4040 — Circuit Breaker Accessories

Schneider Electric EZC100H4040 EasyPact EZC100H Circuit Brea

MPNEZC100H4040
Active

Schneider Electric EasyPact EZC100H series, EZC100H4040, 4-pole circuit breaker, 40 A rated current, thermal-magnetic TM-D trip unit, breaking capacity code H.

$76.41Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100H4040 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100H4040 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]40 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P

Protection & Performance

EZC100H4040 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating40 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100H4040 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width100 mm
Height130 mm
Depth60 mm

Environmental

EZC100H4040 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100H4040 — Approvals
ParameterValue
StandardsGB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-1 EN/IEC 60947-2

Product details

The EZC100H4040 is a 4-pole thermal-magnetic circuit breaker from the EasyPact EZC100H series, rated 40 A at 40 °C (trip unit rated 40 A at 50 °C). The breaking capacity varies by voltage: 100 kA Icu at 110–130 V AC, 50 kA at 220–240 V AC, 30 kA at 380–400 V AC, 20 kA at 440 V AC, and 10 kA at 550 V AC — all conforming to IEC 60947-2. On DC circuits, it delivers 10 kA Icu at 125 V DC (1P) and 250 V DC (2P). For a panel builder, the 100 mm width and 60 mm depth fit a standard backplate mount; front connections (upside and downside) simplify busbar routing.

Integration notes

Mounts on a backplate (fixed mounting) with a 25 mm connection pitch between poles. The toggle control provides positive contact indication — the handle position directly shows whether the contacts are open or closed, even without auxiliary contacts. Rated insulation voltage is 690 V AC; operational voltage is 550 V AC (50/60 Hz) or 250 V DC. IP20 finger-safe terminals and IK07 impact resistance cover basic handling during installation.

Designed to EN/IEC 60947-1 and EN/IEC 60947-2 (the main standard for low-voltage circuit breakers), plus GB/T 14048.2 and JIS C8201-2-2. Pollution degree 3 per IEC 60947. Mechanical durability is rated at 13,000 cycles.

Frequently asked questions

How do I get current pricing and availability for EZC100H4040?

Pricing and availability are confirmed at quote time. Submit an RFQ through this listing; the storefront sources the part through independent distribution and will return current pricing and lead time on request.

What is the closest alternative to EZC100H4040 in the EasyPact family?

Within the EasyPact EZC100H series, the closest alternative is a different trip rating or pole configuration — for example, the EZC100H3030 (3-pole, 30 A) or EZC100H4050 (4-pole, 50 A). No pin-compatible drop-in exists with identical ratings; verify the trip unit rating and pole count against your BOM.

What compliance documentation does Schneider provide for EZC100H4040?

The breaker is certified to EN/IEC 60947-1 and EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It is suitable for isolation per IEC 60947-2. RoHS/REACH documentation is typically available from Schneider Electric's product compliance portal.

MPN
EZC100H4040