Skip to main content
Schneider Electric EZC100H4045 — Circuit Breaker Accessories

Schneider Electric EZC100H4045 EasyPact EZC100H 45A 4P MCCB,

MPNEZC100H4045
Obsolete

Schneider Electric EasyPact EZC100H, EZC100H4045, 4-pole MCCB, 45 A rated current, TM-D thermal-magnetic trip unit, breaking capacity code H (up to 100 kA at 240 V AC).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC100H4045 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100H4045 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]45 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P
EZC100H4045 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating45 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100H4045 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width100 mm
Height130 mm
Depth60 mm
EZC100H4045 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100H4045 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2

Product details

Specification and Compliance

The Schneider Electric EZC100H4045 is a 4-pole moulded-case circuit breaker from the EasyPact EZC100H series, rated at 45 A at 40 °C (trip unit rating 45 A at 50 °C) and built for distribution applications. It uses a thermal-magnetic TM-D trip unit for overload and short-circuit protection, with a toggle control and positive contact indication for local signalling. Per the specification, the breaker is fully compliant with EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2, and is certified for isolation purposes per IEC 60947-2. The breaking capacity (Icu) varies by voltage: 100 kA at 110-130 V AC, 50 kA at 220-240 V AC, 30 kA at 380-400 V AC and 415 V AC, 20 kA at 440 V AC, and 10 kA at 550 V AC and at 125 V DC (1P) or 250 V DC (2P). This H breaking capacity code indicates high-interrupting performance for the frame size.

This MCCB is designed for fixed mounting on a backplate, with front connections on both the line and load sides. The connection pitch is 25 mm. Panel cut-out dimensions are defined by the width (100 mm), height (130 mm), and depth (60 mm). IP20 finger protection is provided on the front face; the enclosure rating IK07 per EN 50102 offers impact resistance. The 4-pole configuration protects three phases (3t) with no neutral protection. It is rated for category A utilization (not intended for frequent switching of motors under load) and is suitable for isolation, meaning it can be used as a disconnecting means in a distribution panel.

No official successor has been announced; the EasyPact EZC100H series remains the current offering in this frame size.

Frequently asked questions

Where can I buy EZC100H4045 and how do I get a price?

The EZC100H4045 is sourced to order against an RFQ through independent distribution. Submit a request for quotation (RFQ) to confirm current availability and pricing at the time of your order.

What compliance documentation does the EZC100H4045 provide?

The breaker is certified to EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. It carries an IP20 front-face protection rating and IK07 impact resistance per EN 50102. The datasheet confirms suitability for isolation per IEC 60947-2.

What is the breaking capacity of EZC100H4045 at 400 V AC?

At 380-400 V AC 50/60 Hz, the ultimate breaking capacity (Icu) is 30 kA per IEC 60947-2. At 415 V AC it is also 30 kA.

MPN
EZC100H4045