Skip to main content
Schneider Electric EZC100H4060 — Circuit Breaker Accessories

Schneider Electric EZC100H4060 EasyPact EZC100H Circuit Brea

MPNEZC100H4060
Active

Schneider Electric EasyPact EZC100H, EZC100H4060, 4-pole circuit breaker, 60 A, TM-D thermal-magnetic trip unit, 10-100 kA breaking capacity, IEC 60947-2.

$76.41Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100H4060 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100H4060 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]60 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P

Protection & Performance

EZC100H4060 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating60 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100H4060 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width100 mm
Height130 mm
Depth60 mm

Environmental

EZC100H4060 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100H4060 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1 JIS C8201-2-2

Product details

The Schneider Electric EZC100H4060 is a 4-pole EasyPact EZC100H moulded-case circuit breaker rated 60 A at 40 °C, with a TM-D thermal-magnetic trip unit that provides both overload and short-circuit protection in one device. Breaking capacity varies by voltage: 100 kA Icu at 110-130 V AC, 50 kA at 220-240 V AC, 30 kA at 380-400 V AC, 20 kA at 440 V AC, 10 kA at 550 V AC, and 10 kA at 125 V DC / 250 V DC. The 'H' breaking capacity code indicates the high-interrupting version of the EZC100H family.

The breaker carries approvals to EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1, and JIS C8201-2-2. It is rated IK07 for mechanical impact resistance and IP20 for finger-safe terminal protection.

Integration notes

Mounts fixed to a backplate (not DIN rail). Dimensions are 130 mm high, 100 mm wide, 60 mm deep. Connection pitch is 25 mm. Both line and load connections are on the front face, simplifying busbar and cable routing in a panel layout. The TM-D trip unit is rated 60 A at 50 °C; the breaker's continuous current rating is 60 A at 40 °C. Mechanical endurance is 13,000 cycles. Toggle control with positive contact indication gives a clear visual of contact position. Three poles are protected (3t); the fourth pole is switched but not protected — no neutral protection is fitted.

Frequently asked questions

What is the breaking capacity of the EZC100H4060?

Breaking capacity varies by voltage: 100 kA Icu at 110-130 V AC, 50 kA at 220-240 V AC, 30 kA at 380-400 V AC, 20 kA at 440 V AC, 10 kA at 550 V AC, and 10 kA at 125 V DC or 250 V DC, all per IEC 60947-2.

Where can I buy the EZC100H4060?

The EZC100H4060 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance standards does the EZC100H4060 meet?

The breaker complies with EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1, and JIS C8201-2-2. It is rated IP20 for finger protection and IK07 for impact resistance.

MPN
EZC100H4060