Skip to main content
Schneider Electric EZC100H4063 — Circuit Breaker Accessories

Schneider Electric EZC100H4063 EasyPact EZC100H 63 A 4P Circ

MPNEZC100H4063
Active

Schneider Electric EasyPact EZC100H, EZC100H4063, 4-pole circuit breaker, 63 A, TM-D thermal-magnetic trip unit, H breaking capacity (10-100 kA), IEC 60947-2.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100H4063 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100H4063 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]63 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description4P

Protection & Performance

EZC100H4063 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeH
Trip unit technologyThermal-magnetic
Trip unit rating63 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100H4063 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100H
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width100 mm
Height130 mm
Depth60 mm

Environmental

EZC100H4063 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100H4063 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2

Product details

The EZC100H4063 is a 4-pole EasyPact EZC100H circuit breaker from Schneider Electric, rated 63 A at 40 °C with a TM-D thermal-magnetic trip unit. The H breaking capacity code means it delivers 30 kA Icu at 380-400 V AC and 100 kA Icu at 110-130 V AC — enough to handle high-fault distribution panels without cascading upstream. The 63 A rating at 50 °C versus 63 A at 40 °C tells you the trip unit holds its full rating up to 50 °C; above that, you derate per the thermal curve. Mounting is fixed to a backplate with front connections and a 25 mm connection pitch. The 100 mm width × 130 mm height × 60 mm depth (-) fits standard panel layouts; the IP20 enclosure means it's protected against solid objects larger than 12 mm but not against moisture — keep it inside a dry enclosure.

Designed and tested to EN/IEC 60947-2, EN/IEC 60947-1, GB/T 14048.2, and JIS C8201-2-2. IK07 impact resistance means it withstands a 2 J hammer blow — robust for panel installation. The toggle control gives positive contact indication so you can visually confirm the contact position.

Frequently asked questions

Where can I buy EZC100H4063 and how do I get a price?

The EZC100H4063 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the closest alternative to EZC100H4063 in the EasyPact family?

Within the EasyPact EZC100H range, the closest alternative would be a different trip rating or pole configuration — the same frame and breaking capacity class. No pin-compatible drop-in exists with a different rating; the TM-D trip unit is specific to the 63 A setting. For a different current, select the corresponding EZC100H variant with the desired In.

What compliance documentation does Schneider provide for EZC100H4063?

The breaker is certified to EN/IEC 60947-2, EN/IEC 60947-1, GB/T 14048.2, and JIS C8201-2-2. It carries a CE mark for the European market. RoHS and REACH declarations are typically available from Schneider Electric's documentation portal for the EasyPact range.

MPN
EZC100H4063