Skip to main content
Schneider Electric EZC100N1016 — Circuit Breaker Accessories

Schneider Electric EZC100N1016 EasyPact EZC100N Circuit Brea

MPNEZC100N1016
Active

Schneider Electric EasyPact EZC100N circuit breaker, EZC100N1016, 16 A thermal-magnetic TM-D trip unit, 1-pole, 25 kA Icu at 110-130 V AC, IP20, current production.

$39.96Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZC100N1016 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100N1016 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]16 A at 40 °C
Rated operational voltage [Ue]125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description1P
EZC100N1016 — Protection & Performance
ParameterValue
Breaking capacity25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]2.5 kA at 125 V DC conforming to IEC 60947-2 9 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating16 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100N1016 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width25 mm
Height130 mm
Depth60 mm
EZC100N1016 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to EN 50102
Pollution degree3 conforming to IEC 60947
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100N1016 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2 JIS C8201-2-2

Product details

The Schneider Electric EZC100N1016 is a 1-pole EasyPact EZC100N circuit breaker with a thermal-magnetic TM-D trip unit rated 16 A at 50 °C. It provides short-circuit and overload protection for distribution circuits. The breaker is designed for fixed backplate mounting with front connections, and uses a toggle for manual control. Rated operational voltage covers 415 V AC 50/60 Hz and 125 V DC, with an insulation voltage of 690 V AC. Breaking capacity reaches 25 kA Icu at 110-130 V AC, 18 kA at 220-240 V AC, and 5 kA at 125 V DC (1-pole). This makes it suitable for branch-circuit protection in panelboards and distribution boards where moderate fault levels are expected. The breaker carries IP20 protection (finger-safe terminals) and IK07 impact resistance. It is certified for isolation per IEC 60947-2, meaning it can be used as a disconnecting means when locked off.

Integration notes

Width of 25 mm and depth of 60 mm fit standard backplate layouts. The 25 mm connection pitch matches common terminal-block spacing. Front connections simplify wiring in tight enclosures. Positive contact indication provides visual confirmation of the contact position. Mechanical durability of 13,000 cycles is adequate for distribution duty where switching is infrequent.

Frequently asked questions

Where can I buy EZC100N1016?

The EZC100N1016 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings for EZC100N1016?

16 A thermal-magnetic trip unit, 1-pole, breaking capacity 25 kA Icu at 110-130 V AC, rated operational voltage 415 V AC / 125 V DC, insulation voltage 690 V AC.

MPN
EZC100N1016