Skip to main content
Schneider Electric EZC100N1025 — Circuit Breaker Accessories

Schneider EasyPact EZC100N1025 25A 1P MCCB, 25 kA Icu

MPNEZC100N1025
Active

Schneider Electric EasyPact EZC100N, 1-pole MCCB, 25 A TM-D trip unit, 25 kA Icu at 110-130 V AC, 18 kA at 240 V AC, 2.5 kA at 415 V AC, IEC 60947-2.

$59.95Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC100N1025 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC100N1025 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]25 A at 40 °C
Rated operational voltage [Ue]125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description1P
EZC100N1025 — Protection & Performance
ParameterValue
Breaking capacity25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 9 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 1.25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating25 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication
EZC100N1025 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width25 mm
Height130 mm
Depth60 mm
EZC100N1025 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC100N1025 — Approvals
ParameterValue
StandardsJIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

The Schneider Electric EasyPact EZC100N1025 is a 1-pole (1P) moulded-case circuit breaker (MCCB) from the EasyPact EZC100N series, fitted with a TM-D thermal-magnetic trip unit rated at 25 A at 50 °C. Breaking capacity (Icu) reaches 25 kA at 110-130 V AC, 18 kA at 220-240 V AC, and 2.5 kA at 400-415 V AC — all per IEC 60947-2. At 125 V DC, 1-pole configuration delivers 5 kA Icu. Rated insulation voltage (Ui) is 690 V AC, and rated operational voltage (Ue) covers 415 V AC and 125 V DC. The breaker is certified for isolation per IEC 60947-2, meaning it provides a visible-break isolation function when open. Pollution degree 3 (IEC 60664-1) suits it for typical panel environments where conductive pollution may occur.

Connection pitch is 25 mm, matching the 25 mm width per pole — a standard 1-module footprint for DIN-rail-compatible MCCBs. Depth is 60 mm, height 130 mm. IP20 finger-safe protection on the front face; IK07 impact resistance per IEC 62262. The toggle actuator provides positive contact indication, so the operator can visually confirm the contact position.

Designed and tested to JIS C8201-2-2, EN/IEC 60947-2, GB/T 14048.2, and EN/IEC 60947-1. The IEC 60947-2 certification covers low-voltage switchgear and controlgear — specifically circuit-breaker performance, breaking capacity, and isolation function. Mechanical durability is rated at 13,000 cycles. No earth-leakage protection module is integrated; neutral protection is not provided (1P, no neutral pole).

Frequently asked questions

What are the key ratings of the EZC100N1025?

Rated current 25 A at 40 °C (25 A at 50 °C on the TM-D trip unit). Breaking capacity 25 kA Icu at 110-130 V AC, 18 kA at 220-240 V AC, 2.5 kA at 400-415 V AC, and 5 kA at 125 V DC. Rated insulation voltage 690 V AC, operational voltage 415 V AC / 125 V DC. 1 pole, thermal-magnetic trip.

Where can I buy the EZC100N1025?

The EZC100N1025 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance documentation does Schneider provide for EZC100N1025?

The breaker is certified to EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It carries an IP20 protection rating and IK07 impact resistance. Specific RoHS/REACH/UL documentation should be requested at quote time as it varies by manufacturing batch.

MPN