Skip to main content
Schneider Electric EZC100N1045

Schneider Electric EZC100N1045 EasyPact EZC100N Circuit Brea

MPN EZC100N1045
Obsolete

Schneider Electric EasyPact EZC100N, circuit breaker, EZC100N1045, 1-pole, 45 A rated current, 25 kA Icu breaking capacity, thermal-magnetic TM-D trip unit, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC100N1045 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage125 V DC conforming to IEC 60947-2 415 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

EZC100N1045 additional specifications
ParameterValue
Temp storage min-35 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width25 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100N1045 is a 1-pole EasyPact EZC100N circuit breaker with a thermal-magnetic TM-D trip unit rated 45 A at 50 °C. That 45 A rating governs the continuous load it can carry without tripping on thermal overload — sized for a distribution subfeed or a moderate motor branch circuit. The breaking capacity code N delivers 25 kA Icu at 110–130 V AC and 18 kA at 220–240 V AC, which means it safely interrupts fault currents up to those levels without welding contacts or cascading upstream. At 380–400 V AC the Icu drops to 2.5 kA, so verify the available fault current at the point of installation — this breaker is not a high-SCCR choice for 400 V three-phase panels.

Deployment context

Mounts fixed to a backplate with front-connect wiring — no DIN-rail clip, so plan for panel cutouts and screw-down termination. The 25 mm width per pole keeps the footprint tight in a multi-pole group.

Certified to EN/IEC 60947-1, EN/IEC 60947-2, GB/T 14048.2, and JIS C8201-2-2. Rated insulation voltage 690 V AC, operational voltage 125 V DC or 415 V AC. Suitability for isolation confirmed per IEC 60947-2 — can be used as a disconnecting means with positive contact indication.

MPN
EZC100N1045