Skip to main content
Schneider Electric EZC100N3020 — Circuit Breaker Accessories

Schneider Electric EZC100N3020 EasyPact EZC100N Circuit Brea

MPNEZC100N3020
Active

Schneider Electric EasyPact EZC100N, EZC100N3020, 3-pole thermal-magnetic circuit breaker, 20 A rated current, 10 kA Icu at 440 V AC, TM-D trip unit.

$49.96Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100N3020 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100N3020 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]20 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P

Protection & Performance

EZC100N3020 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating20 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100N3020 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm

Environmental

EZC100N3020 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100N3020 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 JIS C8201-2-2 EN/IEC 60947-2 GB/T 14048.2

Product details

The Schneider Electric EZC100N3020 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC100N series, rated 20 A at 40 °C with a TM-D trip unit. It provides short-circuit and overload protection for distribution circuits in fixed-mount backplate panels. At 380 V AC the breaking capacity rises to 18 kA Icu, and at 240 V AC to 25 kA Icu, giving flexibility across common supply voltages.

The trip unit rating is 20 A at 50 °C, while the rated current [In] is listed as 20 A at 40 °C. Rated operational voltage (Ue) goes to 550 V AC and 250 V DC, covering most industrial AC supplies and DC control circuits.

Fixed mounting on a backplate — no DIN-rail adapter, so plan for screw-mounting in the panel. Connection pitch is 25 mm, which matches standard distribution-block spacing. The toggle control provides positive contact indication — you can see the mechanism position, not just a flag. IP20 finger-safe front; IK07 impact resistance handles accidental tool drops during commissioning.

Certified to EN/IEC 60947-1, EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. Mechanical durability is 13,000 cycles — adequate for a distribution breaker that cycles infrequently.

Frequently asked questions

Who supplies EZC100N3020 and how is it quoted for volume purchases?

The EZC100N3020 is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is the closest alternative to EZC100N3020 in the EasyPact family?

Within the same EZC100N frame, the closest sibling would be a different trip rating — the mechanical footprint, breaking capacity, and terminal layout are identical across the range. The deciding factor is the load current: select the variant whose TM-D trip rating matches your circuit's continuous load.

What is EZC100N3020's listed depth?

The depth is 60 mm.

What is EZC100N3020's listed width?

The width is 75 mm.

What compliance documentation does Schneider provide for EZC100N3020?

The breaker carries certifications to EN/IEC 60947-1, EN/IEC 60947-2, JIS C8201-2-2, and GB/T 14048.2. It is suitable for isolation per IEC 60947-2. RoHS and REACH declarations are standard Schneider documentation available on request.

MPN
EZC100N3020