Skip to main content
Schneider Electric EZC100N3025 — Circuit Breaker Accessories

EZC100N3025 EasyPact EZC100N 25A 3P Circuit Breaker, 10kA

MPNEZC100N3025
Obsolete

Schneider Electric EasyPact EZC100N, 3-pole circuit breaker, 25 A thermal-magnetic TM-D trip unit, 10 kA Icu at 440 V AC, IEC 60947-2.

$49.96Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100N3025 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100N3025 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]25 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P

Protection & Performance

EZC100N3025 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating25 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100N3025 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm

Environmental

EZC100N3025 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100N3025 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-1 EN/IEC 60947-2 JIS C8201-2-2

Product details

The EZC100N3025 is a 3-pole EasyPact EZC100N circuit breaker with a thermal-magnetic TM-D trip unit rated 25 A at 40 °C (25 A at 50 °C). For a distribution panel feeding a 25 A lighting or small motor load, this is the right pick. Breaking capacity is the real selector here. At 400…415 V it jumps to 15 kA, and at 380 V it hits 18 kA. For a 220…240 V supply, it clears 25 kA. For isolation duty, it's certified per IEC 60947-2, meaning the open contacts provide a visible gap you can lock out. Mounting is fixed (backplate) with front-front connections — both line and load terminate on the front face, which simplifies busbar layout in a panel. The 25 mm connection pitch matches standard distribution busbar systems. IP20 finger-safe terminals, IK07 impact resistance.

The EZC100N3025 carries approvals to GB/T 14048.2, EN/IEC 60947-1, EN/IEC 60947-2, and JIS C8201-2-2. That's the full suite for distribution circuit breakers in industrial and commercial panels — the IEC 60947-2 mark is what most specifiers need for a switchboard or MCC.

Frequently asked questions

How do I get current pricing and availability for EZC100N3025?

Submit an RFQ with the order code and quantity. We source this active part through independent distribution and confirm availability and current pricing at quote time — no stock count or price figure is published here because both change with the supply chain.

What is EZC100N3025's breaking capacity at 440 V AC?

The Icu (ultimate breaking capacity) is 10 kA at 440 V AC 50/60 Hz per IEC 60947-2. At 400…415 V it rises to 15 kA, and at 380 V to 18 kA.

What compliance documentation does this brand provide for EZC100N3025?

The breaker is certified to GB/T 14048.2, EN/IEC 60947-1, EN/IEC 60947-2, and JIS C8201-2-2. It carries IP20 finger protection and IK07 impact resistance. Isolation suitability is confirmed per IEC 60947-2.

MPN