Specifications

EZC100N3063 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch25 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC100N3063 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width75 mm
Height130 mm
Mechanical life cycles13000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC100N3063 is a 3-pole EasyPact EZC100N moulded-case circuit breaker with a 63 A thermal-magnetic trip unit (TM-D) rated at 50 °C. It delivers 10 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2, with higher interrupting ratings at lower voltages — 25 kA at 220–240 V AC and 18 kA at 380–400 V AC.

Breaking capacity and application context

At 415 V AC it holds 15 kA, and at 380–400 V AC it reaches 18 kA, giving headroom for systems with higher available fault current at lower line voltages. The 5 kA Icu at 125 V DC (1-pole) and 250 V DC (2-pole) covers DC distribution sub-circuits, though the primary application is AC distribution per the device application field. The IP20 finger-safe terminals and IK07 impact resistance suit panel-mount installations where incidental contact is possible.