Schneider Electric EZC100N3080 — Circuit Breaker Accessories

Schneider Electric EZC100N3080 EasyPact EZC100N MCCB, 80 A,

MPNEZC100N3080
Active

Schneider Electric EasyPact EZC100N, MCCB, 3-pole, 80 A (TM-D), 10 kA Icu at 440 V AC, thermal-magnetic, IEC 60947-2.

$49.96Ref. price · indicative, final on quote
StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

EZC100N3080 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution

Electrical

EZC100N3080 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]80 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P

Protection & Performance

EZC100N3080 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating80 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability13000 cycles
Local signallingPositive contact indication

Mechanical

EZC100N3080 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC100N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm

Environmental

EZC100N3080 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C

Approvals

EZC100N3080 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-1

Product details

The Schneider Electric EZC100N3080 is a 3-pole EasyPact EZC100N moulded-case circuit breaker (MCCB) with a thermal-magnetic TM-D trip unit, rated 80 A at 40 °C ambient and 80 A at 50 °C. The TM-D trip combines a thermal bimetal for overload protection and a magnetic coil for short-circuit protection. Breaking capacity is the key selection parameter for fault duty. This breaker carries an N breaking capacity code with an Icu of 10 kA at 440 V AC. At 400…415 V AC the Icu rises to 15 kA, and at 380 V AC it reaches 18 kA. For DC applications, the Icu is 5 kA at 125 V DC (1-pole) and 5 kA at 250 V DC (2-pole). This MCCB is a Category A device, meaning it is not specifically designed for selectivity under short-circuit conditions with other breakers downstream — coordination studies should account for that.

The EZC100N3080 is a fixed-mount MCCB intended for backplate mounting in distribution panels or enclosures. Its dimensions are 130 mm height × 75 mm width × 60 mm depth. The 25 mm connection pitch matches standard busbar or cable-lug spacing. Both line and load connections are front-facing, simplifying wiring access in a panel layout. The IP20 degree of protection means it is finger-safe but not sealed against moisture — install it inside a cabinet rated for the environment.

Frequently asked questions

What is the breaking capacity of the EZC100N3080 at 440 V?

The breaking capacity (Icu) is 10 kA at 440 V AC 50/60 Hz per IEC 60947-2.

What compliance documentation is available for the EZC100N3080?

The breaker is certified to EN/IEC 60947-2, GB/T 14048.2, JIS C8201-2-2, and carries an IK07 impact rating. Documentation includes the IEC standard test reports and the manufacturer's declaration of conformity.