Skip to main content
Schneider Electric EZC250F3160 — Circuit Breaker Accessories

Schneider Electric EZC250F3160 EasyPact EZC250F 160A 3P Circ

MPNEZC250F3160
Active

Schneider Electric EasyPact EZC250F series, EZC250F3160, 3-pole circuit breaker, 160 A thermal-magnetic TM-D trip unit, breaking capacity 25 kA at 240 V AC, fixed mounting, front connections.

$95.43Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250F3160 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250F3160 — Electrical
ParameterValue
Network type (AC/DC)AC DC
Rated current [In]160 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC250F3160 — Protection & Performance
ParameterValue
Breaking capacity10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeF
Trip unit technologyThermal-magnetic
Trip unit rating160 A at 50 °C
Trip unit nameTM-D
Protection typeOverload protection Short-circuit protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250F3160 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250F
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width105 mm
Height165 mm
Depth60 mm
EZC250F3160 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250F3160 — Approvals
ParameterValue
StandardsGB/T 14048.2 EN/IEC 60947-1 EN/IEC 60947-2

Product details

The Schneider Electric EZC250F3160 is a 3-pole EasyPact EZC250F circuit breaker with a thermal-magnetic TM-D trip unit rated 160 A at 40 °C (160 A at 50 °C). The fixed-mount design with front connections and a 35 mm connection pitch integrates into a backplate-mounted panel.

Breaking capacity varies with voltage: 25 kA Icu at 240 V AC, 18 kA at 380 V, 15 kA at 400–415 V, and 10 kA at 440 V AC. At 550 V AC it drops to 5 kA; in DC, 5 kA at 125 V (1P) or 250 V (2P). This F-code breaker (breaking capacity code F) is sized for downstream distribution panels where fault currents stay within those limits — coordination with an upstream higher-kA device is expected for high-SCCR service entrances.

Mounts fixed to a backplate with front-facing line and load connections — no DIN-rail adapter. IP20 finger-safe enclosure (IK07 impact rating) suits indoor panel installation.

Designed to GB/T 14048.2, EN/IEC 60947-1, and EN/IEC 60947-2. The toggle control provides positive contact indication. No earth-leakage or neutral protection built in — this is a straight 3-pole (3t) thermal-magnetic breaker for three-phase distribution. Rated insulation voltage 690 V AC; rated operational voltage up to 550 V AC or 250 V DC.

MPN