Schneider Electric EZC250H3225

Schneider Electric EZC250H3225 EasyPact EZC250H 225A 3P Circ

MPN EZC250H3225
Active

Schneider Electric EasyPact EZC250H series, EZC250H3225, 3P 225A thermal-magnetic circuit breaker, 36 kA Icu at 400 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250H3225 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZC250H3225 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Depth60 mm
Width105 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC250H3225 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC250H series, rated 225 A at 40 °C and carrying a TM-D trip unit for overload and short-circuit protection. At 550 V AC it drops to 10 kA Icu, so if your line side is a 480 V or 550 V transformer, the available fault current at that point must stay under 10 kA or you need a current-limiting upstream device.

Fixed backplate mounting with front-facing connections. Dimensions are 165 mm high × 105 mm wide × 60 mm deep.

Positive contact indication gives a visible gap confirmation for lockout/tagout. The 10,000-cycle mechanical durability is typical for a distribution breaker; if your application cycles the breaker weekly as a disconnect, that is roughly a 200-year life — not a constraint. The manufacturer provides RoHS, REACH, and CE declarations; UL/CSA listing is not stated in the evidence, so verify with your local Schneider representative if North American approvals are required.