Schneider Electric EZC250N3225 — Circuit Breaker Accessories

Schneider Electric EZC250N3225 EasyPact EZC250N, 225A, 20kA

MPNEZC250N3225
Active

Schneider Electric EasyPact EZC250N series, EZC250N3225, 3-pole thermal-magnetic circuit breaker, 225 A rated current, 20 kA Icu at 440 V AC, TM-D trip unit, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

EZC250N3225 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact
Device applicationDistribution
EZC250N3225 — Electrical
ParameterValue
Network type (AC/DC)DC AC
Rated current [In]225 A at 40 °C
Rated operational voltage [Ue]550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Rated insulation voltage [Ui]690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZC250N3225 — Protection & Performance
ParameterValue
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity [Ics]10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeN
Trip unit technologyThermal-magnetic
Trip unit rating225 A at 50 °C
Trip unit nameTM-D
Protection typeShort-circuit protection Overload protection
Earth-leakage protectionWithout
Suitability for isolationYes conforming to IEC 60947-2
Utilisation categoryCategory A
Mechanical durability10000 cycles
Local signallingPositive contact indication
EZC250N3225 — Mechanical
ParameterValue
Connection pitch35 mm
Downside connectionFront
Upside connectionFront
Device short nameEasypact EZC250N
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width105 mm
Height165 mm
Depth60 mm
EZC250N3225 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Operating ambient air temperature-25...70 °C
Storage ambient air temperature-35...85 °C
EZC250N3225 — Approvals
ParameterValue
StandardsEN/IEC 60947-2 GB/T 14048.2 EN/IEC 60947-1

Product details

The Schneider Electric EZC250N3225 is a 3-pole thermal-magnetic circuit breaker from the EasyPact EZC250N series, rated 225 A at 40 °C and carrying a TM-D trip unit. The 690 V AC rated insulation voltage (Ui) and 550 V AC maximum operational voltage (Ue) cover most 400/480 V distribution panels.

The 225 A rating at 40 °C is the continuous current the breaker carries without tripping in a 40 °C ambient; at 50 °C the same trip unit is rated 225 A, so no derating is required up to that point. For a distribution panel feeding a 225 A bus, this breaker is the main or a large feeder; the 20 kA Icu at 440 V AC is the maximum fault current it can clear once, and the 25 kA Icu at 400 V AC gives a bit more headroom at common European voltages. The 8 kA Icu at 550 V AC is the limit if the system runs at that voltage — rare in distribution, but the rating is there.

Deployment context

The breaker mounts fixed to a backplate with front connections — typical for panel-mounted distribution in switchboards or enclosure backplates. IP20 means finger-safe but not sealed — install inside a cabinet rated for the environment. The toggle control provides positive contact indication for visual confirmation of open/closed state.

Frequently asked questions

How do I get current pricing and availability for EZC250N3225?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time.

What is the closest alternative to EZC250N3225 in the EasyPact family?

Within the EasyPact EZC250N series, the closest alternative would be a unit with the same frame size and trip rating but a different breaking capacity code (e.g., H for high or S for standard). The EZC250N3225 uses the N (normal) breaking capacity — 20 kA at 440 V AC. A higher-breaking-capacity variant (H code) would be needed if the available fault current exceeds 20 kA at that voltage. No pin-compatible drop-in exists with a different trip unit technology; the TM-D is fixed thermal-magnetic.

What compliance documentation does Schneider provide for EZC250N3225?

The breaker is certified to EN/IEC 60947-2 and GB/T 14048.2, with suitability for isolation per IEC 60947-2. IP20 per IEC 60529 and IK07 per IEC 62262. Pollution degree 3 per IEC 60664-1. Standard documentation includes the declaration of conformity and the IEC test certificate; RoHS and REACH declarations are available from Schneider's documentation portal.

MPN
EZC250N3225