Skip to main content
Schneider Electric EZC250N44225

Schneider EasyPact EZC250N44225 MCCB, 225 A, 20 kA

MPN EZC250N44225
Obsolete

Schneider Electric EasyPact EZC250N, 4-pole MCCB, 225 A thermal-magnetic TM-D trip unit, 20 kA Icu at 440 V AC, IP20, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250N44225 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC250N44225 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EasyPact EZC250N44225 is a 4-pole moulded-case circuit breaker (MCCB) from the EasyPact EZC250N series, fitted with a TM-D thermal-magnetic trip unit rated 225 A at 50 °C. The TM-D trip provides overload and short-circuit protection via a thermal-magnetic mechanism — the thermal element handles sustained overcurrents, the magnetic element clears high-fault events instantly. No earth-leakage protection is built in (specified as 'Without').

The EZC250N44225 carries a breaking capacity code 'N' and delivers 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V AC the rating rises to 25 kA Icu; at 220–240 V AC it reaches 50 kA Icu. For DC circuits, it is rated 20 kA Icu at 125 V DC (1-pole) and 20 kA Icu at 250 V DC (2-pole). At 550 V AC the rating drops to 8 kA Icu — a key constraint if your line voltage runs high. The breaker is utilisation category A, meaning it is not intended for frequent switching of motor loads under normal conditions — it is a distribution breaker, not a motor-protective device.

Fixed-mount design for backplate installation. Front-front connections (both line and load side terminate on the front face), which simplifies busbar routing in a panel but means you need clearance in front for cable access. The connection pitch is 35 mm. IP20 finger-safe protection on the front; the enclosure itself is rated IK07 for impact resistance. Dimensions: 165 mm high, 140 mm wide, 60 mm deep.

Designed and tested to IEC 60947-1 and IEC 60947-2, with additional compliance to JIS C8201-2-2 and GB/T 14048.2.

MPN
EZC250N44225