Schneider Electric EZC400N44350N

Schneider Electric EZC400N44350N EasyPact EZC400N, 400 A, 36

MPN EZC400N44350N
Obsolete

Schneider Electric EasyPact EZC400N, molded case circuit breaker, EZC400N44350N, 400 A rated current at 40 °C, 36 kA Icu at 440 V AC, 4 poles, TM-D thermal-magnetic trip unit, fixed mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC400N44350N key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC400N44350N additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
ColorBlack
Depth140 mm
Width185 mm
Height255 mm
Electrical life cyclesCategory A: 4000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZC400N44350N is a 4-pole molded case circuit breaker from the EasyPact EZC400N series, rated 400 A at 40 °C with a TM-D thermal-magnetic trip unit. It provides short-circuit and overload protection in distribution applications, with a breaking capacity of 36 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2.

The magnetic trip is fixed at 3200 A, roughly 8× In, so it handles motor inrush without nuisance tripping on Category A utilisation. Electrical durability is 4000 cycles at 415 V; mechanical durability is 10,000 cycles. For frequent switching applications, that cycle count sets the replacement interval.

Fixed-mount design for backplate installation. Front-front connection — both line and load terminate on the front face, simplifying busbar routing in a panel. The 45 mm pole pitch is standard for 400 A frame MCCBs. IP20 finger-safe protection and IK07 impact resistance cover basic panel-side handling. Dimensions: 255 mm high × 185 mm wide × 140 mm deep.

MPN