Schneider Electric EZCV250N4080 — Molded Case Circuit Breakers (MCCB)

Schneider Electric EZCV250N4080 EasyPact EZCV250N, 80 A, 20

MPNEZCV250N4080
Obsolete

Schneider Electric EasyPact EZCV250N, EZCV250N4080, 4-pole molded case circuit breaker, 80 A thermal-magnetic trip unit, 20 kA Icu at 440 V AC, earth-leakage protection, IP20, backplate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

EZCV250N4080 — Identification
ParameterValue
Product / component typeCircuit breaker
Device applicationDistribution
EZCV250N4080 — Mechanical
ParameterValue
Height165 mm
Width140 mm
Depth68 mm
EZCV250N4080 — Electrical
ParameterValue
[In] rated current80 A at 40 °C
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage440 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage440 V AC 50/60 Hz conforming to IEC 60947-2
EZCV250N4080 — Specifications
ParameterValue
Poles description4P
Trip unit nameTM-D
Trip unit technologyThermal-magnetic
Device short nameEasypact EZCV250N
StandardsGB/T 14048.2 JIS C8201-2-2 EN/IEC 60947-1 EN/IEC 60947-2

Product details

The thermal-magnetic trip provides overload protection (thermal element) and short-circuit protection (magnetic element), plus integrated earth-leakage protection, all in one device. Breaking capacity is the critical figure for fault-withstand capability: 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V AC the rating rises to 25 kA Icu, and at 220–240 V AC to 85 kA Icu — the higher the voltage, the harder it is to quench the arc, so the lower the interrupting rating. For selectivity (discrimination) you would need a Category B breaker with a short-time delay. The EZCV250N4080 is suited for distribution as a main or branch breaker where coordination is handled upstream or by a separate selectivity study.

Deployment context

Mounts fixed to a backplate (not DIN-rail) with front-connect terminals on both line and load sides. The 35 mm connection pitch matches standard busbar systems and panel-mounting patterns. IP20 finger-safe protection is sufficient for enclosed panel installation; the IK07 impact rating means the enclosure withstands a 2 J hammer blow — adequate for industrial cabinet environments where accidental tool strikes occur.

It also complies with GB/T 14048.2 (Chinese national standard) and JIS C8201-2-2 (Japanese industrial standard). The suitability-for-isolation marking (IEC 60947-2) confirms it can be used as a disconnecting means with a visible open gap.

Frequently asked questions

What is the breaking capacity of EZCV250N4080 at 440 V AC?

The breaking capacity is 20 kA Icu at 440 V AC 50/60 Hz per IEC 60947-2. At 380–415 V AC it is 25 kA Icu, and at 220–240 V AC it is 85 kA Icu.

What compliance documentation does this brand provide for EZCV250N4080?

The breaker is certified to EN/IEC 60947-1 and EN/IEC 60947-2, plus GB/T 14048.2 and JIS C8201-2-2. It carries IP20 and IK07 protection ratings and is suitable for isolation per IEC 60947-2.

Where can I buy EZCV250N4080?

The EZCV250N4080 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
EZCV250N4080