Skip to main content
Schneider Electric EZCV250N4125

Schneider Electric EZCV250N4125 EasyPact EZCV250N, 125 A, 4P

MPN EZCV250N4125
Obsolete

Schneider Electric EasyPact EZCV250N, circuit breaker, 125 A at 40 °C, 4P, 20 kA Icu at 440 V AC, TM-D thermal-magnetic trip unit, earth-leakage protection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZCV250N4125 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui440 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C

All specifications

EZCV250N4125 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth68 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZCV250N4125 is a 4-pole molded case circuit breaker from the EasyPact EZCV250N series, rated 125 A at 40 °C with a TM-D thermal-magnetic trip unit. It carries a 20 kA Icu breaking capacity at 440 V AC (50/60 Hz) per IEC 60947-2, which means it can safely interrupt fault currents up to that level without upstream damage — the key number for panel coordination. The breaker also includes integral earth-leakage protection, so it handles both overload/short-circuit and ground-fault detection in one device, saving a separate relay and CT.

Above that ambient, you derate per the thermal curve — a panel running at 50 °C will need a higher-frame breaker or active cooling. The 85 kA Icu at 220–240 V shows the breaker's arc chamber is sized for high-fault residential or light commercial secondaries, but the 20 kA at 440 V is the number that governs most industrial distribution panels. The TM-D trip unit is a fixed thermal-magnetic design — no interchangeable trip plugs.

Fixed backplate mount, front-front connections (both line and load on the front face). At 140 mm wide × 165 mm high × 68 mm deep, it fits a standard distribution section without crowding — three of these side-by-side in a 480 mm wide enclosure leaves room for cable ducts. The toggle handle gives positive contact indication (visible red/green flag), so an operator can confirm open/closed state through the panel door cutout.

MPN