Schneider Electric EasyPact EZCV250N, molded case circuit breaker, 225 A at 40 °C, 4 poles, TM-D thermal-magnetic trip unit, 20 kA Icu at 440 V AC, front connection.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZCV250N4225 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage440 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui440 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZCV250N4225 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth68 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric EZCV250N4225 is a 4-pole molded case circuit breaker from the EasyPact EZCV250N series, rated 225 A at 40 °C with a TM-D thermal-magnetic trip unit. It is designed for distribution applications and carries an IEC 60947-2 breaking capacity of 20 kA Icu at 440 V AC, 50/60 Hz. The TM-D trip unit provides overload, short-circuit, and earth-leakage protection.

The breaker is part of the EasyPact range, which is Schneider's economy molded case circuit breaker line positioned below the Compact NSX series. It is a direct replacement for older TeSys GV and GV2 series breakers in distribution applications, sharing the same mounting footprint and connection pitch.

The breaker mounts fixed to a backplate with a 35 mm connection pitch and front-facing connections on both line and load sides. The 140 mm width and 165 mm height fit standard distribution panel cutouts. The IP20 finger-safe protection is sufficient for enclosed panels; the IK07 impact rating means it withstands accidental tool strikes during installation. The toggle control provides positive contact indication — the handle position directly reflects the contact state, which is required for isolation applications. The breaker is certified for isolation per IEC 60947-2, meaning it can be used as a disconnecting means in a panel.

The breaker complies with EN/IEC 60947-2, JIS C8201-2-2, EN/IEC 60947-1, and GB/T 14048.2.