Skip to main content
Schneider Electric EZS100E3025 — Circuit Breaker Accessories

Schneider Electric EZS100E3025 EasyPact EZS Circuit Breaker,

MPNEZS100E3025
Obsolete

Schneider Electric EasyPact EZS, circuit breaker, 25 A at 40 °C, 3 poles, thermal-magnetic TM-D trip unit, breaking capacity 50 kA Icu at 240 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

EZS100E3025 — Identification
ParameterValue
Product / component typeCircuit breaker
Range of productEasyPact EZS
EZS100E3025 — Electrical
ParameterValue
Network type (AC/DC)AC
Rated current [In]25 A at 40 °C
Rated operational voltage [Ue]440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2
Rated insulation voltage [Ui]690 V conforming to EN/IEC 60947-2
Rated impulse withstand voltage [Uimp]6 kV conforming to EN/IEC 60947-2
Network frequency50/60 Hz
Poles description3P
EZS100E3025 — Protection & Performance
ParameterValue
Breaking capacity50 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 17 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 200/230 V AC 50/60 Hz conforming to GB 14048.2 25 kA Icu at 380/400 V AC 50/60 Hz conforming to GB 14048.2
Rated service breaking capacity [Ics]25 kA at 220/230 V AC 50/60 Hz conforming to GB 14048.2 13 kA at 380/400 V AC 50/60 Hz conforming to GB 14048.2 25 kA at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity codeE
Trip unit technologyThermal-magnetic
Trip unit rating25 A at 40 °C
Trip unit nameTM-D
Protection typeShort-circuit protection (magnetic) Overload protection (thermal)
Suitability for isolationYes
Utilisation categoryCategory A
Mechanical durability13000 cycles conforming to EN/IEC 60947-2 20000 cycles conforming to GB 14048.2
Electrical durability4000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2
EZS100E3025 — Mechanical
ParameterValue
Connection pitch25 mm
Downside connectionFront
Upside connectionFront
Device short nameEZS100E
Control typeToggle
Mounting modeFixed
Mounting supportBackplate
Width75 mm
Height130 mm
Depth60 mm
EZS100E3025 — Environmental
ParameterValue
IP degree of protectionIP40 conforming to IEC 60529
IK degree of protectionIK07 conforming to IEC 62262
Pollution degree3 conforming to IEC 60947-1
Operating ambient air temperature-35...70 °C
Storage ambient air temperature-50...85 °C
EZS100E3025 — Approvals
ParameterValue
StandardsEN 60947-2 IEC 60947-2

Product details

Its TM-D trip unit provides fixed long-time protection at 1 In and magnetic short-circuit protection, with an integral instant protection rating of 300 kA.

Breaking capacity and compliance

Breaking capacity is specified per EN/IEC 60947-2: 50 kA Icu at 220/240 V AC, 25 kA at 380/400 V AC, 25 kA at 415 V AC, and 17 kA at 440 V AC. For installations governed by GB 14048.2, the same 25 kA at 380/400 V AC applies.

Fixed mounting on a backplate with a 25 mm connection pitch. Dimensions are 130 mm height, 75 mm width, and 60 mm depth. Front-connect terminals on both line and load sides simplify busbar or cable routing in a panel. The neutral position is left. IP40 enclosure protection and IK07 impact resistance are suitable for enclosed distribution boards where occasional tool contact or minor mechanical shock may occur.

Frequently asked questions

What is EZS100E3025's listed depth (60 mm) on this component line?

The EZS100E3025 has a depth of 60 mm, a width of 75 mm, and a height of 130 mm.

MPN