It is a distribution breaker (category A, no intentional short-time delay) built to EN/IEC 60947-2. At 240 V AC it handles 50 kA Icu. The front-front connection (both line and load from the front) and 25 mm connection pitch match standard panel layouts. The toggle control and fixed mounting on a backplate keep the installation straightforward.
Schneider Electric EZS100E3040 EasyPact EZS 40A Thermal-Magn
MPNEZS100E3040
Obsolete
Schneider Electric EasyPact EZS, EZS100E3040, 3-pole thermal-magnetic circuit breaker, 40 A at 40 °C, 25 kA Icu at 400 V AC, EN/IEC 60947-2.
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Circuit breaker |
| Range of product | EasyPact EZS |
| Parameter | Value |
|---|---|
| Network type (AC/DC) | AC |
| Rated current [In] | 40 A at 40 °C |
| Rated operational voltage [Ue] | 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 400 V AC 50/60 Hz conforming to GB 14048.2 |
| Rated insulation voltage [Ui] | 690 V conforming to EN/IEC 60947-2 |
| Rated impulse withstand voltage [Uimp] | 6 kV conforming to EN/IEC 60947-2 |
| Network frequency | 50/60 Hz |
| Poles description | 3P |
| Parameter | Value |
|---|---|
| Breaking capacity | 50 kA Icu at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 17 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 40 kA Icu at 200/230 V AC 50/60 Hz conforming to GB 14048.2 25 kA Icu at 380/400 V AC 50/60 Hz conforming to GB 14048.2 |
| Rated service breaking capacity [Ics] | 25 kA at 220/230 V AC 50/60 Hz conforming to GB 14048.2 13 kA at 380/400 V AC 50/60 Hz conforming to GB 14048.2 25 kA at 220/240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA at 380/400 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Breaking capacity code | E |
| Trip unit technology | Thermal-magnetic |
| Trip unit rating | 40 A at 40 °C |
| Trip unit name | TM-D |
| Protection type | Short-circuit protection (magnetic) Overload protection (thermal) |
| Suitability for isolation | Yes |
| Utilisation category | Category A |
| Mechanical durability | 13000 cycles conforming to EN/IEC 60947-2 20000 cycles conforming to GB 14048.2 |
| Electrical durability | 4000 cycles 415 V In/2 conforming to EN/IEC 60947-2 8000 cycles 400 V In conforming to GB 14048.2 |
| Parameter | Value |
|---|---|
| Connection pitch | 25 mm |
| Downside connection | Front |
| Upside connection | Front |
| Device short name | EZS100E |
| Control type | Toggle |
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Width | 75 mm |
| Height | 130 mm |
| Depth | 60 mm |
| Parameter | Value |
|---|---|
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Pollution degree | 3 conforming to IEC 60947-1 |
| Operating ambient air temperature | -35...70 °C |
| Storage ambient air temperature | -50...85 °C |
| Parameter | Value |
|---|---|
| Standards | EN 60947-2 IEC 60947-2 |
Product details
Frequently asked questions
What is EZS100E3040's listed depth (60 mm) on this component line?
The depth is 60 mm. Combined with a width of 75 mm and height of 130 mm, the breaker fits standard backplate-mounted distribution panels.
What is EZS100E3040's listed width (75 mm) on this component line?
The width is 75 mm. This is the standard 3-pole width for the EasyPact EZS100E frame.
MPN
EZS100E3040