Skip to main content
Schneider Electric GBX0800201403F — Gear Reducers & Gearboxes

Schneider Electric GBX0800201403F Planetary Gearbox, 20:1

MPNGBX0800201403F
Obsolete

Schneider Electric GBX0800201403F planetary gearbox, 80 mm diameter, 20:1 reduction, 120 N.m continuous torque, 14 arc.min backlash, IP54 shaft output.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GBX0800201403F — Identification
ParameterValue
Product / component typePlanetary gearbox
Gearbox typeStraight teeth
Compatibility codeGBX
Device short nameGBX
GBX0800201403F — Performance
ParameterValue
Reduction ratio20:1
Output torque, max.1699.3 lbf.in (192 N.m) 100 rpm 86 °F (30 °C)
Output torque, continuous1062.09 lbf.in (120 N.m) 100 rpm 86 °F (30 °C)
Torsional backlash, max.14 arc.min
Efficiency94 %
Torsional rigidity6.5 N.m/arcmin
Service life30000 h 100 rpm 86 °F (30 °C)
Noise level60 dB 1 m, no-load
GBX0800201403F — Mechanical
ParameterValue
Axial force (Fa), max.1200 N 100 rpm, during 10000 hour at 30°C 900 N 100 rpm, during 30000 hour at 30°C
Radial force (Fr), max.650 N 100 rpm, force applied at mid-distance from output shaft during 30000 hour at 30 °C 950 N 100 rpm, force applied at mid-distance from output shaft during 10000 hour at 30 °C
Gearbox outer diameter3.1 in (80 mm)
Housing materialBlack anodized aluminium
Shaft materialC 45
GBX0800201403F — Environmental
ParameterValue
IP protection ratingShaft output IP54
Ambient operating temperature-13...194 °F (-25...90 °C)

Product details

Obsolete status and sourcing path

The GBX0800201403F: The replacement path requires reviewing the application's torque, ratio, and mounting envelope against current GBX-series offerings.

Torque ratings and duty cycle

Rated for 120 N.m continuous output torque at 100 rpm and 30 °C, with a maximum output torque of 192 N.m under the same conditions — the extra headroom handles peak loads during acceleration or momentary overloads without immediate damage. Service life is specified at 30,000 hours at 100 rpm and 30 °C, lubricated for life — no maintenance oil changes required over the service interval. The 94 % efficiency figure means 6 % of input power is lost as heat through the straight-teeth mesh.

Shaft loading and environmental limits

Maximum radial force on the output shaft is 650 N at mid-span for the full 30,000-hour service life; axial force is limited to 900 N over the same interval. Exceeding these loads shortens bearing life proportionally. The shaft output carries an IP54 rating — protected against dust ingress and splashing water, but not submersion. Ambient operating range is -25 °C to 90 °C; the black anodized aluminium housing dissipates heat but should not be enclosed without ventilation in high-duty-cycle applications.

MPN
GBX0800201403F