Skip to main content
Schneider Electric GBX1200040703F — Gear Reducers & Gearboxes

Schneider Electric GBX1200040703F Planetary Gearbox, 4:1

MPNGBX1200040703F
Obsolete

Schneider Electric GBX1200040703F planetary gearbox, straight teeth, 120 mm diameter, 4:1 reduction ratio, 155 N.m continuous output torque, 94 % efficiency, IP54 shaft output.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GBX1200040703F — Identification
ParameterValue
Product / component typePlanetary gearbox
Gearbox typeStraight teeth
Compatibility codeGBX
Device short nameGBX
GBX1200040703F — Performance
ParameterValue
Reduction ratio4:1
Output torque, max.2195.0 lbf.in (248 N.m) 100 rpm 86 °F (30 °C)
Output torque, continuous1371.9 lbf.in (155 N.m) 100 rpm 86 °F (30 °C)
Torsional backlash, max.8 arc.min
Efficiency94 %
Torsional rigidity12 N.m/arcmin
Service life30000 h 100 rpm 86 °F (30 °C)
Noise level65 dB 1 m, no-load
GBX1200040703F — Mechanical
ParameterValue
Axial force (Fa), max.2100 N 100 rpm, during 30000 hour at 30°C 2800 N 100 rpm, during 10000 hour at 30°C
Radial force (Fr), max.1500 N 100 rpm, force applied at mid-distance from output shaft during 30000 hour at 30 °C 2000 N 100 rpm, force applied at mid-distance from output shaft during 10000 hour at 30 °C
Gearbox outer diameter4.7 in (120 mm)
Housing materialBlack anodized aluminium
Shaft materialC 45
GBX1200040703F — Environmental
ParameterValue
IP protection ratingShaft output IP54
Ambient operating temperature-13...194 °F (-25...90 °C)

Product details

Torque ratings and duty cycle

The GBX1200040703F: The continuous output torque is 155 N.m at 100 rpm and 30 °C, with a maximum output torque of 248 N.m under the same conditions — the continuous figure governs the steady-state load, while the maximum covers transient overloads during acceleration or jams. Service life is rated at 30,000 hours at 100 rpm and 30 °C, with the gearbox lubricated for life and sealed per IP54 at the shaft output — no maintenance re-lubrication interval to schedule.

Mechanical interface and load limits

The 120 mm diameter housing is black anodized aluminium; the output shaft is C45 steel. Maximum axial force Fa is 2100 N at 100 rpm for the 30,000-hour life target, and 2800 N for a 10,000-hour duty. Maximum radial force Fr is 1500 N at mid-span on the output shaft for the longer life, and 2000 N for the shorter. Torsional rigidity is 12 N.m/arcmin, and maximum torsional backlash is 8 arc.min — the stiffness figure tells you how much wind-up occurs under load, while the backlash spec sets the position repeatability floor for reversing or indexing applications.

Lifecycle status — obsolete

Schneider Electric lists the GBX1200040703F as obsolete. Sourcing is through independent distribution channels; quantities and pricing are confirmed at RFQ against the BOM line.

Frequently asked questions

What is the continuous torque rating of GBX1200040703F?

The continuous output torque is 155 N.m at 100 rpm and 30 °C. The maximum output torque is 248 N.m under the same conditions, which covers transient overloads.

What is the efficiency of GBX1200040703F?

The listed efficiency is 94 %. This is the mechanical efficiency at rated load, accounting for gear mesh and bearing losses in the planetary stage.

MPN
GBX1200040703F