Skip to main content
Schneider Electric GS2AM110 — Auxiliary Contacts

TeSys GS2AM110 Auxiliary Contact, 1 NO, Early-Break, Obsolet

MPNGS2AM110
Obsolete

Schneider Electric TeSys GS2AM110, auxiliary contact block, 1 NO, early-break, for GS1 32 A disconnect with direct front handle.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GS2AM110 — Identification
ParameterValue
Product typeAuxiliary contact
Product range / familyTeSys
GS2AM110 — Ratings
ParameterValue
Rated operational current (Ie), by utilization category3 A 240 V AC-15 6 A 120 V AC-15 1.5 A 480 V AC-15 1.8 A 400 V AC-15 2.8 A 24 V DC-13 0.15 A 400 V DC-13 0.27 A 250 V DC-13 0.55 A 125 V DC-13 1.4 A 48 V DC-13
Conventional free-air thermal current (Ith)16 A (at 104 °F (40 °C))
GS2AM110 — Performance
ParameterValue
Mechanical durability (cycles)5000000 cycles
GS2AM110 — Other specifications
ParameterValue
Contact operationEarly-break
Device short nameGS2AM
Contact applicationO, I and test position signalling
Switch rated current1250 A 50 A 200 A 125 A 160 A 400 A 600 A 63 A 800 A 100 A 250 A 32 A 60 A 315 A 630 A
Electrical durability1000000 cycles AC-15
Type of operating handleExternal left side External right side External frontal
Contacts type and composition1 NO

Product details

The GS2AM110 is an auxiliary contact block from the TeSys GS range, designed as a 1 NO early-break contact for the GS1 32 A disconnect switch with a direct front handle. It signals the O, I, and test positions of the disconnect, giving the control system a positive indication of switch state.

Rated operational current (Ie) covers both AC-15 and DC-13 loads: 6 A at 120 V AC-15, 3 A at 240 V AC-15, and 1.5 A at 480 V AC-15 — these are the inductive load ratings for solenoid and contactor coils typical in control circuits. For DC control, it handles 2.8 A at 24 V DC-13 and 0.55 A at 125 V DC-13, but drops to 0.15 A at 400 V DC-13.

Mounts on the left or right side of the GS1 disconnect, or on the front, using the external handle. The early-break contact opens before the main disconnect contacts, which is used to drop control power or signal a pending shutdown before the load circuit opens. Mechanical durability is rated at 5,000,000 cycles; electrical durability at 1,000,000 cycles under AC-15 duty.

Frequently asked questions

What is the GS2AM110 used for?

It is an early-break auxiliary contact block for the TeSys GS1 32 A disconnect switch. It signals the O, I, and test positions of the handle to a control system, and the early-break timing means it opens before the main disconnect contacts, which is useful for dropping control power ahead of the load.

What are the key electrical ratings of the GS2AM110?

Rated operational current includes 6 A at 120 V AC-15, 3 A at 240 V AC-15, and 1.5 A at 480 V AC-15 for AC inductive loads. For DC, it is 2.8 A at 24 V DC-13 and 0.55 A at 125 V DC-13. The conventional free air thermal current is 16 A at 40 °C.

MPN
GS2AM110