Skip to main content
Schneider Electric GS2G4 — Contactors

Schneider TeSys GS2G4 Switch-Disconnector-Fuse, 4P 63A, DIN

MPNGS2G4
Active

Schneider Electric TeSys GS switch-disconnector-fuse, 4 poles, 63 A, DIN fuse size 000, IP20 with terminal cover.

$278.64Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GS2G4 — Identification
ParameterValue
Product / component typeSwitch-disconnector-fuse
Series / rangeTeSys
GS2G4 — Contacts & Poles
ParameterValue
Pole configuration4P
GS2G4 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529 (with terminal cover)
Fire resistance850 °C fuse cover conforming to IEC 60695-2-1 960 °C body conforming to IEC 60695-2-1
GS2G4 — Approvals
ParameterValue
StandardsIEC 60947-3
GS2G4 — Mechanical
ParameterValue
Width168 mm
Height118 mm
Depth116.5 mm

Product details

It accepts DIN-style fuse links in size 000, making it a straightforward line-side disconnect and short-circuit protection device for motor feeders and distribution sub-circuits. Rated operational current is 63 A across AC-23A and AC-23B duty at 400 V, 500 V, and 690 V — the AC-23 category covers motor loads with occasional overloads, so this switch handles starting inrush without nuisance opening. Breaking capacity is 500 A at 400 V (AC-23B); making capacity is 630 A at the same voltage, which means it can close onto a faulted circuit up to that peak. Rated operational power reaches 30 kW at 400 V, 40 kW at 500 V, and 55 kW at 690 V — match these to your motor nameplate to confirm the switch is sized for the load.

Mounts to a plate (not DIN rail), so plan for a drilled backplate or a sub-panel. The 4-pole footprint is 168 mm wide × 118 mm high × 116.5 mm deep — compact enough for a motor control centre bucket. Power-circuit terminals accept lugs or ring terminals from 10 to 25 mm²; tighten to 3.2 N·m. The operating handle can be mounted externally on the front or the right side — useful when the switch lives deep inside an enclosure and you need the handle on the door.

Frequently asked questions

What standard does the GS2G4 comply with?

It is designed and tested to IEC 60947-3, the standard for switch-disconnectors and fuse-combination units. Rated impulse withstand voltage is 8 kV, and the short-circuit withstand is 10.6 kA.

What fuse size does it accept?

DIN fuse links, size 000. The fuse cover withstands 850 °C per IEC 60695-2-1; the body withstands 960 °C.

MPN