Skip to main content
Schneider Electric GV2DP105FE7 — Miniature Circuit Breakers (MCB)

TeSys Deca GV2DP105FE7 DOL Starter, 0.63-1 A, 115 V AC

MPNGV2DP105FE7
Active

Schneider Electric TeSys Deca GV2DP105FE7 DOL combination starter, non-reversing, 0.63-1 A thermal protection, 115 V AC 50/60 Hz coil, 3-pole, Type 2 coordination.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DP105FE7 — Identification
ParameterValue
Product range (series)TeSys Deca
Product/component typeMotor starter
GV2DP105FE7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DP105FE7 — Mechanical
ParameterValue
Width45 mm
Height176.4 mm
Depth105.6 mm
GV2DP105FE7 — Other specifications
ParameterValue
Motor power0.25 kW at 400/415 V AC 50/60 Hz 0.37 kW at 400/415 V AC 50/60 Hz 0.25 kW at 440 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz
Coordination typeType 2
Device short nameGV2DP
Device composition1 combination block GV2AF3 1 3-pole contactor 1 motor circuit breaker type GV2P
Motor starter typeNon reversing
Breaking capacityIq 130 kA at 400/415 V conforming to IEC 60947-4-1 Iq 130 kA at 440 V conforming to IEC 60947-4-1 Iq 130 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current13 A
Coil voltage115 V AC 50/60 Hz
Thermal protection adjustment range0.63...1 A

Product details

The GV2DP105FE7 is a non-reversing DOL combination starter from the TeSys Deca range — a pre-assembled block that pairs a GV2P motor circuit breaker with a 3-pole contactor on a GV2AF3 base. It ships as one unit, saving panel space and wiring time over separate components. Thermal protection adjusts from 0.63 to 1 A, so it covers small motors — think fractional-horsepower pumps, fans, or conveyor drives — on 400/415 V or 440 V supplies. At 400/415 V it handles 0.25 kW; at 440 V it also covers 0.37 kW. The coil pulls 115 V AC 50/60 Hz. Magnetic trip is fixed at 13 A — that's the instantaneous short-circuit threshold, well above the thermal band, so it won't nuisance-trip on normal motor inrush.

Rated breaking capacity hits 130 kA at 400/415 V and 440 V, tested to IEC 60947-4-1. Type 2 coordination means the contactor and breaker are matched so that under a short circuit the contactor remains serviceable — no contact welding, minimal damage. AC-3 utilisation category confirms it's rated for starting and stopping squirrel-cage motors — the duty cycle that matters for most industrial motor loads.

The block measures 45 mm wide, 105.6 mm deep, and 176.4 mm tall.

Frequently asked questions

What is the thermal protection adjustment range on GV2DP105FE7?

The thermal protection adjustment range is 0.63 to 1 A.

What is the breaking capacity of GV2DP105FE7?

The rated breaking capacity is 130 kA at 400/415 V and 440 V, tested to IEC 60947-4-1.

Where can I buy GV2DP105FE7?

The GV2DP105FE7 is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN