Schneider Electric GV2DP116FE7 — Miniature Circuit Breakers (MCB)

TeSys Deca GV2DP116FE7 DOL Motor Starter, 9…14 A, 115 V AC

MPNGV2DP116FE7
Obsolete

TeSys Deca, DOL combination motor starter, GV2DP116FE7, 9…14 A thermal protection, 115 V AC 50/60 Hz coil, 3-pole, non-reversing.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DP116FE7 — Identification
ParameterValue
Product range (series)TeSys Deca
Product/component typeMotor starter
GV2DP116FE7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DP116FE7 — Mechanical
ParameterValue
Width45 mm
Height186.8 mm
Depth111.9 mm
GV2DP116FE7 — Other specifications
ParameterValue
Motor power5.5 kW at 400/415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 7.5 kW at 440 V AC 50/60 Hz 9 kW at 500 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz
Coordination typeType 2
Device short nameGV2DP
Device composition1 motor circuit breaker type GV2P 1 combination block GV2AF3 1 3-pole contactor
Motor starter typeNon reversing
Breaking capacityIq 130 kA at 400/415 V conforming to IEC 60947-4-1 Iq 50 kA at 440 V conforming to IEC 60947-4-1 Iq 42 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current170 A
Coil voltage115 V AC 50/60 Hz
Thermal protection adjustment range9...14 A

Product details

The GV2DP116FE7 is a DOL combination motor starter from the TeSys Deca range — a factory-assembled unit that pairs a GV2P motor circuit breaker, a GV2AF3 combination block, and a 3-pole contactor into one non-reversing starter. It's sized for motor loads in the 9…14 A thermal protection adjustment range, with a 115 V AC 50/60 Hz control coil. The thermal adjustment range (9…14 A) is what you set to match the motor full-load current — the overload relay inside the breaker protects the motor from sustained overcurrent. The magnetic trip is fixed at 170 A, which clears short-circuit faults fast enough to achieve Type 2 coordination, meaning the contactor and downstream components survive a fault without damage. Rated breaking capacity is 130 kA at 400/415 V per IEC 60947-4-1, 50 kA at 440 V, and 42 kA at 500 V — that's the maximum fault current the starter can safely interrupt. The motor power ratings span 5.5 kW at 400/415 V up to 9 kW at 500 V, all in AC-3 duty (starting squirrel-cage motors).

This part is listed as Obsolete by the manufacturer.

The starter measures 45 mm wide, 186.8 mm high, and 111.9 mm deep — a standard compact footprint for a 3-pole combination starter.

Frequently asked questions

Where can I buy GV2DP116FE7?

We source GV2DP116FE7 to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What are the key ratings for GV2DP116FE7?

Thermal protection adjustment range is 9…14 A, control voltage is 115 V AC 50/60 Hz, magnetic trip is 170 A, and breaking capacity is 130 kA at 400/415 V per IEC 60947-4-1. Motor power ratings go up to 9 kW at 500 V in AC-3 duty.

What is GV2DP116FE7's width for panel layout?

The width is 45 mm, which fits a single 45 mm-wide DIN-rail position in a standard enclosure.