Skip to main content
Schneider Electric GV2DP102F7 — Miniature Circuit Breakers (MCB)

Schneider GV2DP102F7 TeSys Deca DOL Starter, 0.16-0.25 A, Ob

MPNGV2DP102F7
Obsolete

Schneider Electric TeSys Deca GV2DP102F7 DOL combination starter, 0.16…0.25 A thermal protection range, 110 V AC coil, 3-pole non-reversing, Type 2 coordination, 130 kA breaking capacity at 400/415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV2DP102F7 — Identification
ParameterValue
Product range (series)TeSys Deca
Product/component typeMotor starter
GV2DP102F7 — Ratings
ParameterValue
Poles configuration3P
Utilisation categoryAC-3
GV2DP102F7 — Mechanical
ParameterValue
Width45 mm
Height176.4 mm
Depth105.6 mm
GV2DP102F7 — Other specifications
ParameterValue
Motor power0.06 kW at 400/415 V AC 50/60 Hz 0.06 kW at 440 V AC 50/60 Hz
Coordination typeType 2
Device short nameGV2DP
Device composition1 motor circuit breaker type GV2P 1 combination block GV2AF3 1 3-pole contactor
Motor starter typeNon reversing
Breaking capacityIq 130 kA at 400/415 V conforming to IEC 60947-4-1 Iq 130 kA at 440 V conforming to IEC 60947-4-1 Iq 130 kA at 500 V conforming to IEC 60947-4-1
Magnetic tripping current2.4 A
Thermal protection adjustment range0.16...0.25 A

Product details

The Schneider Electric GV2DP102F7 is a direct-on-line (DOL) combination motor starter from the TeSys Deca range, factory-assembled as a single unit containing a GV2P motor circuit breaker, a GV2AF3 combination block, and a 3-pole contactor with a 110 V AC coil. It provides thermal and magnetic motor protection over a 0.16…0.25 A adjustment range.

Rated for AC-3 utilization category, this starter is sized for a 0.06 kW motor on 400/415 V or 440 V supplies — suitable for small pumps, fans, or conveyors where DOL starting is acceptable. The magnetic tripping current is set at 2.4 A, which clears short-circuit faults before the contactor welds; the listed breaking capacity of 130 kA at 400/415 V (per IEC 60947-4-1) means the unit can safely interrupt faults up to that prospective level without upstream fuse damage, provided the supply network's fault current is within that limit. Type 2 coordination ensures the contactor remains operational after a fault — no contact welding under the rated short-circuit condition.

The unit occupies a 45 mm wide footprint on a DIN rail, with a depth of 105.6 mm and height of 176.4 mm. The pre-assembled composition eliminates separate breaker-contactor wiring, saving panel space and reducing assembly time on the line.

Frequently asked questions

How do I get current pricing and availability for GV2DP102F7?

The GV2DP102F7 is sourced through independent distribution and quoted to order against an RFQ. Availability and pricing are confirmed at the time of the quote.

What is the closest pin-compatible alternative to GV2DP102F7 in this component family?

Schneider Electric does not list a direct pin-compatible successor for the GV2DP102F7. For new designs, consult the current TeSys Deca or TeSys island catalog for a functionally equivalent DOL starter with similar thermal range and breaking capacity.

What is GV2DP102F7's listed depth (105.6 mm) on this component line?

The GV2DP102F7 has a depth of 105.6 mm.

What is GV2DP102F7's listed width (45 mm) on this component line?

The GV2DP102F7 has a width of 45 mm.

MPN