Skip to main content
Schneider Electric GV4LE02S6 — Motor Protection Circuit Breakers (MPCB)

Schneider TeSys GV4LE02S6 Motor Circuit Breaker, 2 A, 120 kA

MPNGV4LE02S6
Active

Schneider Electric TeSys Deca GV4L motor circuit breaker, GV4LE02S6, 3-pole, 2 A rated current, magnetic-electronic trip, 120 kA breaking capacity at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GV4LE02S6 — Mechanical
ParameterValue
Height155 mm
Width81 mm
Depth116 mm

Product details

Rated at 2 A continuous (In), this breaker protects small motors — think fractional-horsepower pumps, fans, or conveyors — across a wide voltage range: it covers 0.25 kW at 400 V up to 1.5 kW at 690 V. That 2 A figure is the trip rating, not the load current you set it to; you'd dial it to match the motor's full-load amps, and the magnetic trip kicks in between 12 and 28 A for short-circuit protection.

The GV4LE02S6 carries a 120 kA Icu at 240 V AC, dropping to 100 kA at 415 V, 70 kA at 440 V, and 10 kA at 690 V. It meets both EN/IEC 60947-2 (circuit breaker standard) and EN/IEC 60947-4-1 (motor starter standard), so it's certified for motor branch circuit protection as a combined motor protector — not just a distribution breaker.

Panel integration and mechanical fit

Mounts in any position, so you're not locked into a specific orientation inside the enclosure. The 27 mm connection pitch without spreaders (35 mm with) matches typical motor starter layouts; you'll need ring-terminal lugs on the power cables, with a 9 N·m torque for the main terminals (16–95 mm² cable) and 5 N·m for the control terminals (1.5–10 mm²). IP40 front-of-panel protection, IK07 impact resistance — fine for a dry indoor cabinet, but not washdown-rated. The grey RAL 7016 housing is standard for the TeSys Deca line.

Frequently asked questions

What is the closest alternative to GV4LE02S6 in the TeSys family?

Within the same TeSys Deca GV4L family, the closest alternative would be a different current rating — for example, the GV4LE03S6 at 3 A or GV4LE01S6 at 1 A. They share the same physical footprint, breaking capacity, and trip technology; only the 2 A In rating differs. There is no pin-compatible drop-in from the older GV2 or GV3 series because the mounting hole pattern and terminal pitch changed with the Deca line.

What compliance documentation does Schneider provide for GV4LE02S6?

The part is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1. Climatic withstand conforms to IACS. Fire resistance tested to 960 °C per IEC 60695-2-11. It is suitable for isolation per IEC 60947-1. The manufacturer typically provides a Declaration of Performance (DoP), CE/UKCA declaration, and UL/CSA recognition on request — these are standard for the TeSys Deca line.

What are the key specifications for panel fit?

Dimensions are 155 mm high, 81 mm wide, 116 mm deep. Mounts in any position on 35 mm DIN rail or via screw lugs. Connection pitch is 27 mm without spreaders, 35 mm with. Terminal torque: 9 N·m for 16–95 mm² cable, 5 N·m for 1.5–10 mm² cable. IP40 front protection, IK07 impact resistance.

MPN
GV4LE02S6