Schneider TeSys GV4LE02S6 Motor Circuit Breaker, 2 A, 120 kA

MPN GV4LE02S6
Obsolete

Schneider Electric TeSys Deca GV4L motor circuit breaker, GV4LE02S6, 3-pole, 2 A rated current, magnetic-electronic trip, 120 kA breaking capacity at 240 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE02S6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4LE02S6 additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles40000 cycles for AC-3 at 440 V In/2 40000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

Rated at 2 A continuous (In), this breaker protects small motors — think fractional-horsepower pumps, fans, or conveyors — across a wide voltage range: it covers 0.25 kW at 400 V up to 1.5 kW at 690 V. That 2 A figure is the trip rating, not the load current you set it to; you'd dial it to match the motor's full-load amps, and the magnetic trip kicks in between 12 and 28 A for short-circuit protection.

The GV4LE02S6 carries a 120 kA Icu at 240 V AC, dropping to 100 kA at 415 V, 70 kA at 440 V, and 10 kA at 690 V. It meets both EN/IEC 60947-2 (circuit breaker standard) and EN/IEC 60947-4-1 (motor starter standard), so it's certified for motor branch circuit protection as a combined motor protector — not just a distribution breaker.

Panel integration and mechanical fit

Mounts in any position, so you're not locked into a specific orientation inside the enclosure. The 27 mm connection pitch without spreaders (35 mm with) matches typical motor starter layouts; you'll need ring-terminal lugs on the power cables, with a 9 N·m torque for the main terminals (16–95 mm² cable) and 5 N·m for the control terminals (1.5–10 mm²). IP40 front-of-panel protection, IK07 impact resistance — fine for a dry indoor cabinet, but not washdown-rated. The grey RAL 7016 housing is standard for the TeSys Deca line.