Schneider Electric GV4LE50B — Motor Protection Circuit Breakers (MPCB)

Schneider Electric GV4LE50B TeSys Deca Motor Circuit Breaker

MPNGV4LE50B
Obsolete

Schneider Electric TeSys Deca GV4L series, GV4LE50B motor circuit breaker, 3-pole, 50 A rated current, magnetic electronic trip, breaking capacity 50 kA at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

GV4LE50B — Mechanical
ParameterValue
Height155 mm
Width81 mm
Depth116 mm

Product details

Breaking capacity reaches 50 kA Icu at 240 V AC, 25 kA at 415 V, and 10 kA at 500 V — figures that govern fault-clearing capability for the connected motor branch circuit.

Motor power and trip characteristics

Motor power ratings span 11 kW at 400 V up to 45 kW at 690 V, depending on the supply voltage. The magnetic trip is adjustable between 300 and 700 A, providing short-circuit protection that coordinates with the motor's starting inrush. The trip unit technology is magnetic electronic — a hybrid approach that uses a magnetic coil for instantaneous fault detection and an electronic module for overload curve shaping. This avoids the thermal drift of bimetal designs and allows tighter protection bands.

Dimensions are 155 mm high, 81 mm wide, and 116 mm deep. The grey (RAL 7016) enclosure carries IP40 protection (finger-safe) and IK07 impact resistance. EverLink BTR screw terminals accept cable from 1.5 to 95 mm², with separate torque values for power and control connections.

Durability and environmental ratings

Mechanical durability is 40,000 cycles; electrical durability under AC-3 duty at 440 V is 10,000 cycles at rated current, doubling to 20,000 cycles at half load. Maximum operating rate is 25 cycles per hour — a constraint for frequent start-stop applications. Climatic withstand conforms to IACS (marine environmental testing). Vibration resistance covers 2 to 100 Hz at 0.7 gn, and shock withstand is 15 gn for 11 ms.

Certified to EN/IEC 60947-4-1 (motor starters) and EN/IEC 60947-2 (circuit breakers). Fire resistance tested at 960 °C per IEC 60695-2-11. The utilisation category is AC-3 for motor switching and Category A for distribution-level short-circuit protection.

Frequently asked questions

What are the key ratings for the GV4LE50B?

Rated current is 50 A continuous. Breaking capacity is 50 kA at 240 V AC, 25 kA at 415 V, and 10 kA at 500 V. Motor power ranges from 11 kW at 400 V to 45 kW at 690 V. The magnetic trip is adjustable 300–700 A.

What standards does the GV4LE50B comply with?

It is certified to EN/IEC 60947-4-1 (motor protection) and EN/IEC 60947-2 (circuit breaker). It also carries suitability for isolation per IEC 60947-1 and fire resistance at 960 °C per IEC 60695-2-11.

What is the closest alternative to the GV4LE50B in the TeSys Deca range?

Within the same GV4L family, the GV4LE40B is the 40 A variant and the GV4LE63B is the 63 A variant. These share the same frame size, terminal specifications, and breaking capacity — the only difference is the continuous current rating and the corresponding trip curve settings. There is no pin-compatible alternative outside the TeSys Deca range that matches the form, fit, and function exactly.