Skip to main content
Schneider Electric GV4LE50N6

Schneider GV4LE50N6 TeSys GV4 Motor Circuit Breaker, 50 A, 1

MPN GV4LE50N6
Active

Schneider Electric TeSys GV4 series, GV4LE50N6 motor circuit breaker, 3-pole, 50 A rated current, 100 kA breaking capacity at 240 V AC, magnetic-electronic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE50N6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C

All specifications

GV4LE50N6 additional specifications
ParameterValue
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles20000 cycles for AC-3 at 440 V In/2 10000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

The GV4LE50N6 is a 3-pole motor circuit breaker from Schneider's TeSys GV4 family, rated 50 A continuous and built to protect motor circuits up to 22 kW at 400 V or 45 kW at 690 V. The magnetic trip window is adjustable from 300 to 700 A, so you set the instantaneous pickup just above the motor's inrush without nuisance tripping on a hard start.

Standards and approvals — what they certify

That dual standard is the key: it acts as both a motor disconnect with overload protection and a branch-circuit short-circuit protective device.

Integration notes — mounting and wiring

Terminal lugs accept cable from 1.5 to 95 mm², with tightening torque of 5 N·m for the smaller wires and 9 N·m for the heavier ones. The connection pitch is 27 mm without spreaders, 35 mm with — that matters when you're laying out a multi-breaker lineup and need to match busbar spacing. Operating position is any orientation, which gives flexibility in tight enclosures. The mechanical durability is 40,000 cycles, electrical durability 20,000 at AC-3 duty at half load, so it's built for frequent switching in conveyor or pump applications.

MPN
GV4LE50N6