Schneider Electric GV4LE50S6 — Motor Protection Circuit Breakers (MPCB)

Schneider Electric GV4LE50S6 TeSys GV4 Motor Circuit Breaker

MPNGV4LE50S6
Active

Schneider Electric TeSys GV4, GV4LE50S6, motor circuit breaker, 3 poles, 50 A In, magnetic electronic trip, AC-3, 120 kA Icu at 240 V.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Mechanical

GV4LE50S6 — Mechanical
ParameterValue
Height155 mm
Width81 mm
Depth116 mm

Product details

The GV4LE50S6 is a 3-pole motor circuit breaker from the TeSys GV4 range, rated 50 A continuous and built for motor protection under AC-3 duty per IEC 60947-4-1. That AC-3 rating means it handles the inrush of a squirrel-cage motor during starting and switches it off under load — the 50 A figure governs the full-load motor current, not just the thermal trip setting. The magnetic electronic trip unit fires between 300 and 700 A for short-circuit protection, so it clears a bolted fault fast without nuisance tripping on normal start-up transients. Breaking capacity is the headline for panel builders doing fault coordination: 120 kA Icu at 240 V, 100 kA at 415 V, and still 10 kA at 690 V. That means it can sit upstream of a smaller MCCB or contactor without needing a current-limiting fuse for most industrial supply transformers. The 690 V rating also makes it usable on 600 V class Canadian and 690 V European line-ups.

Mounts in any position — no derating for side or horizontal orientation. Connection pitch is 27 mm without spreaders, 35 mm with, which matches standard DIN-rail terminal block spacing for clean panel wiring. Lugs or ring terminals on the power side; tightening torque is 9 N·m for the main cables (16–95 mm²) and 5 N·m for the control wiring (1.5–10 mm²). IP40 front panel protection, IK07 impact rating — fine for a dry indoor enclosure, not for washdown.

Operating altitude up to 5000 m, storage temperature from -50 to 85 °C. Climatic withstand per IACS covers marine and humid conditions. Fire resistance at 960 °C per IEC 60695-2-11.

Durability and mechanicals

Mechanical durability is 40,000 cycles; electrical durability at full-load AC-3 is 10,000 cycles at 440 V, or 20,000 cycles at half-load. Maximum operating rate is 25 cycles per hour — fine for a motor starter duty cycle, not for rapid jogging. Vibration resistance to ±1 mm at 2–13.2 Hz and 0.7 g at 13.2–100 Hz; shock rated at 15 g for 11 ms. Power dissipation is 6.1 W per pole, so three poles total about 18.3 W at full load — factor that into enclosure heating calculations.

Frequently asked questions

What is the closest alternative to GV4LE50S6 in the same family?

Within the TeSys GV4 range, the closest peer is the GV4LE50S7 — same 50 A frame but with a different auxiliary contact configuration. The GV4LE50S6 carries the base auxiliary contact arrangement; the S7 variant adds a second set. If your BOM calls for the S6, the S7 is a functional substitute only if the extra auxiliary contact does not conflict with your control circuit wiring.

What compliance documentation does Schneider provide for GV4LE50S6?

The breaker is certified to EN/IEC 60947-2 and EN/IEC 60947-4-1. It carries suitability for isolation per IEC 60947-1. Standard Schneider declarations of conformity (CE, UKCA) and the IEC test certificates are available through the product documentation portal. RoHS and REACH compliance is standard for the TeSys GV4 series.

What are the key ratings for GV4LE50S6?

Rated current 50 A, AC-3 utilisation category, breaking capacity 120 kA Icu at 240 V, rated operational voltage 690 V AC, rated insulation voltage 800 V AC. Motor power ranges from 11 kW at 400 V to 45 kW at 690 V.