Schneider Electric GV4LE80S6

Schneider Electric GV4LE80S6 TeSys GV4 Motor Circuit Breaker

MPN GV4LE80S6
Active

Schneider Electric TeSys GV4 motor circuit breaker, GV4LE80S6, 3-pole, 80 A rated current, 120 kA breaking capacity at 240 V AC, 37 kW at 400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4LE80S6 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity120 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch27 mm without spreaders 35 mm with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C

All specifications

GV4LE80S6 additional specifications
ParameterValue
Storage temperature-50...85 °C
Pollution degree3
ColorGrey (RAL 7016)
Depth116 mm
Width81 mm
Height155 mm
Electrical life cycles14000 cycles for AC-3 at 440 V In/2 7000 cycles for AC-3 at 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-25...70 °C

Product details

It combines magnetic and electronic trip technology to protect against short circuits and overloads, with a breaking capacity of 120 kA Icu at 240 V AC and 100 kA at 415 V AC per IEC 60947-2. The 80 A rating sets the motor full-load current threshold — wire it for a 37 kW motor at 400 V or up to 55 kW at 690 V. Rated for AC-3 duty per IEC 60947-4-1, this breaker handles the inrush of squirrel-cage motors during starting and switching. The magnetic trip range is 480–1120 A, adjustable to coordinate with motor starting characteristics. Continuous duty rated per IEC 60947-4-1 means it carries the 80 A load indefinitely without derating in a 40 °C ambient.

The GV4LE80S6 measures 155 mm high, 81 mm wide, and 116 mm deep — a compact 3-pole footprint for DIN-rail or screw-mount installation in a motor control center. Connection pitch is 27 mm without spreaders, 35 mm with them, accepting lugs or ring terminals up to 95 mm² cable at 9 N·m torque. IP40 front protection keeps out tools and fingers; IK07 impact rating handles panel-door knocks. Operates in any position at altitudes up to 5000 m, with storage from -50 to 85 °C. Fire resistance rated at 960 °C per IEC 60695-2-11.

Approvals include EN/IEC 60947-2 and 60947-4-1, with suitability for isolation per IEC 60947-1. Climatic withstand conforms to IACS for marine and humid environments. No UL listing is stated in the evidence, so verify for North American panel builds.