Skip to main content
Schneider Electric GV4PE80B6

Schneider GV4PE80B6 TeSys Deca Motor Circuit Breaker, 80 A

MPN GV4PE80B6
Obsolete

Schneider Electric TeSys GV4 GV4PE80B6 motor circuit breaker, 80 A, 3-pole, electronic thermal-magnetic trip, 50 kA breaking capacity at 240 V AC, IP40, gray RAL 7016.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

GV4PE80B6 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic Thermal-magnetic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz IEC 60947-2
Breaking capacity50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947
Utilization categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IP ratingIP40
Terminal pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

GV4PE80B6 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-58...185 °F (-50...85 °C)
Pollution degree3
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical life cycles14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-13...158 °F (-25...70 °C)

Product details

The GV4PE80B6 is a 3-pole motor circuit breaker from the TeSys Deca range, rated 80 A line current and built for continuous motor protection duty per IEC 60947-4-1. That 80 A rating sets the thermal overload threshold — the breaker holds continuously at 80 A and trips on sustained overcurrent above that level, protecting the motor winding without nuisance tripping on normal starting inrush. The electronic thermal-magnetic trip unit combines two protection modes: an electronic thermal element that tracks motor heating with an adjustable time curve, and a fixed magnetic trip set at 1360 A for short-circuit protection. Phase failure sensitivity per IEC 60947-4-1 means the breaker detects a lost phase and trips before single-phasing damages the motor — no separate phase-loss relay needed. Under UL 60947, the SCCR is 35 kA at 240 V and 18 kA at 480Y/277 V. These numbers govern your coordination study — the breaker must clear a fault within its rated interrupting capacity without upstream devices having to open.

Isolation and lockout — rated for safe de-energization

The GV4PE80B6 is certified suitable for isolation per IEC 60947-1. That means when the toggle is in the OFF position, the contacts provide a visible air gap that meets the isolation standard — you can positively disconnect the motor for maintenance and lock the toggle. No exceptions: if it's not locked, it's not safe. The toggle control type supports padlock hasp attachment for LOTO compliance.

Certifications and compliance — UL, CSA, IEC on the nameplate

That covers North American and European installations from a single part number — no dual-stock needed for a machine shipping to both markets. The fire resistance rating is 960 °C per IEC 60695-2-11, so it passes the glow-wire test for unattended equipment.

MPN