Specifications

GV4PEM80B6 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic Electronic
Main product or component typeMotor circuit breaker
Voltage690 V AC 50/60 Hz IEC 60947-2
Insulation voltage ui800 V AC 50/60 Hz IEC 60947-2
Breaking capacity50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 35 kA 208Y/120 V AC 50/60 Hz UL 60947 35 kA 240 V AC 50/60 Hz UL 60947 18 kA 480Y/277 V AC 50/60 Hz UL 60947 14 kA 600Y/347 V AC 50/60 Hz UL 60947
Utilization categoryCategory A IEC 60947-2 AC-3 IEC 60947-4-1
IP ratingIP40
Terminal pitch1.06 in (27 mm) without spreaders 1.4 in (35 mm) with spreaders
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

GV4PEM80B6 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-58...185 °F (-50...85 °C)
Pollution degree3
ColorGray RAL 7016)
Depth4.6 in (116 mm)
Width3.2 in (81 mm)
Height6.1 in (155 mm)
Electrical life cycles14000 cycles AC-3 440 V In/2 7000 cycles AC-3 440 V In
Mechanical life cycles40000 cycles
ApplicationMotor protection
Operating positionAny position
Operating temperature-13...158 °F (-25...70 °C)

Product details

Motor circuit breaker for 37 kW at 400 V

The GV4PEM80B6 is a 3-pole motor circuit breaker from the TeSys GV4 range, rated 80 A continuous and designed for motor protection per IEC 60947-4-1 and UL 60947-4-1.

Breaking capacity and trip technology

The trip unit combines thermal-magnetic and electronic elements: the magnetic trip is fixed at 1360 A (17× In), and phase-failure sensitivity is built in per IEC 60947-4-1, so it catches single-phasing before the motor overheats.

Panel fit and environmental specs

Dimensions are 6.1 in (155 mm) high by 3.2 in (81 mm) wide by 4.6 in (116 mm) deep, with a connection pitch of 1.06 in (27 mm) without spreaders or 1.4 in (35 mm) with spreaders — the spreaders give extra clearance for larger cable lugs. Rated IP40 (finger-safe) and IK07 (impact resistance), with pollution degree 3, so it suits industrial control panels where dust and light contaminants are present.

Durability and operating cycle

Mechanical durability is 40,000 cycles; electrical durability under AC-3 at 440 V is 14,000 cycles at 1× In and 7,000 cycles at full rated current. Maximum operating rate is 25 cycles per hour — this breaker is built for occasional switching, not continuous jogging. The continuous duty rating (IEC 60947-4-1) means it can hold rated current indefinitely without derating.

Carries CSA C22.2 No 60947-4-1, UL 60947-4-1, EN/IEC 60947-4-1, and EN/IEC 60947-2 approvals — accepted across North America and Europe without additional certification. Fire resistance tested to 960 °C (IEC 60695-2-11). Suitability for isolation per IEC 60947-1 means it can serve as a visible disconnect in the motor branch circuit.