Schneider Electric GVAED0113 — Auxiliary Contacts

GVAED0113 TeSys Deca Auxiliary Contact Block, 1NO+1NC, Sprin

MPNGVAED0113
Active

Schneider Electric TeSys Deca Frame 2/3 auxiliary contact block, GVAED0113, 1NC+1NO (fault-signal), front-mount, spring-clamp terminals, 2.5 A thermal, 720 VA at 230-240 V AC-15.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

GVAED0113 — Identification
ParameterValue
Product typeAuxiliary contact block
Product range / familyTeSys TeSys Deca
GVAED0113 — Ratings
ParameterValue
Conventional free-air thermal current (Ith)2.5 A
Rated operational voltage (Ue)24...240 V AC 24...60 V DC
GVAED0113 — Performance
ParameterValue
Rated insulation voltage (Ui)600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14
Mechanical durability (cycles)100000 cycles
GVAED0113 — Mechanical
ParameterValue
Width44.5 mm
Height13 mm
Depth31.5 mm
GVAED0113 — Approvals
ParameterValue
StandardsEN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 IEC/EN 60335-1:Clause 30.2 IEC/EN 60335-2-40:Annex JJ

Product details

The Schneider Electric GVAED0113 is a front-mounted auxiliary contact block for the TeSys Deca Frame 2/3 range, used to add a fault-signal contact to GV2 and GV3 manual motor starters (excluding GV3ME). The block provides one normally-open and one normally-closed contact, with the NC contact dedicated as the fault-signal output. Rated conventional free-air thermal current (Ith) is 2.5 A, and the block carries full IEC/UL/CSA certifications for use in control circuits.

Switching capacity and duty ratings

In AC-15 duty (solenoid/contactor control), the block switches up to 720 VA at 230-240 V and 850 VA at 380-415 V, both with 100,000 electrical cycles. In DC-13 duty (solenoid/relay control with parallel diodes), it handles 140 W at 24 V and 120 W at 240 V, also at 100,000 cycles. Minimum switching capability is 5 mA at 17 V — important for low-signal PLC inputs or electronic load interface where dry-contact reliability matters. Mechanical durability is rated at 100,000 cycles, matching the electrical endurance at full load.

The block is certified to EN/IEC 60947-5-1 (control circuit devices), UL 60947-4-1 and CSA C22.2 No 60947-4-1 (motor controllers), plus IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ for glow-wire and heat-resistance in appliance applications. Insulation voltage (Ui) is rated 690 V per IEC 60947-1, 600 V per UL 508 and CSA C22.2 No 14.

Dimensions are 44.5 mm wide, 31.5 mm deep, and 13 mm high — designed to snap onto the front face of TeSys Deca Frame 2/3 motor starters without increasing panel depth significantly. Mounting location is the front side of the starter; the dark-grey housing matches the standard TeSys Deca aesthetic. External protection is required: the evidence specifies a GB2CB circuit breaker or 10 A GG fuse upstream.

Frequently asked questions

What are the key ratings I need to check for fit?

The GVAED0113 is a front-mounted auxiliary contact block for TeSys Deca Frame 2/3 starters (GV2/GV3, excluding GV3ME). Key ratings: 2.5 A thermal current, 720 VA at 230-240 V AC-15, 140 W at 24 V DC-13, minimum 5 mA at 17 V. It has 1NO+1NC contacts with spring-clamp terminals.

What compliance certifications does the GVAED0113 carry?

It carries EN/IEC 60947-5-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and IEC/EN 60335-1 Clause 30.2 and IEC/EN 60335-2-40 Annex JJ for appliance heat-resistance. Insulation voltage is 690 V per IEC, 600 V per UL/CSA.

What is the physical size of the GVAED0113?

It measures 44.5 mm wide by 31.5 mm deep by 13 mm high — designed to mount on the front of the TeSys Deca Frame 2/3 starter.