Skip to main content
Schneider Electric HMIP6ABB0NA0DNAN00

Schneider HMIP6ABB0NA0DNAN00 Harmony P6 Box PC, 4096x2304

MPN HMIP6ABB0NA0DNAN00
Active

Schneider Electric Harmony P6 modular box PC, HMIP6ABB0NA0DNAN00, Intel Atom x6211E, 2 core, 4 GB, 4096 x 2304 display resolution, 12...24 V DC, IP20, NEMA 4X/13.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

HMIP6ABB0NA0DNAN00 specifications
ParameterValue
Main product or component typeModular box PC
IP ratingIP20
NEMA ratingNEMA 4X/13
Temp storage max60 °C
Temp storage min-20 °C
Temp operating max55 °C
Temp operating min0 °C
Storage temperature-4...140 °F (-20...60 °C)
Pollution degree2
Depth1.5 in (37 mm)
Width9.8 in (250 mm)
Height6.5 in (165 mm)
Resolution4096 x 2304 pixels at 60 Hz
Operating temperature32...131 °F (0...55 °C) wall mounting side 32...131 °F (0...55 °C) book mounting side 32...131 °F (0...55 °C) flat mounting top

Product details

The HMIP6ABB0NA0DNAN00 is a Schneider Electric Harmony P6 modular box PC built around an Intel Atom x6211E dual-core processor with 4 GB of RAM. It drives a native 4096 x 2304 pixel display at 60 Hz — 4K resolution on a panel-mount industrial computer — and runs on a 12...24 V DC supply with a wide 9...36 V input tolerance.

Software stack and runtime environment

Node-RED is preinstalled for edge logic and data flow. The unit also ships with EcoStruxure Machine SCADA Expert runtime, EcoStruxure Operator Terminal Expert runtime, and an AVEVA system platform installer — covering SCADA, HMI, and historian roles from one box. Separate licenses are required for EcoStruxure Secure Connect, Stratus EverRun, and Trellix.

Panel-mount footprint: 9.8 in wide by 6.5 in tall by 1.5 in deep. One expansion slot is available for an optional interface card. Operating temperature range is 32 to 131 °F (0 to 55 °C) in wall, book, or flat mounting orientations. Storage range extends from -4 to 140 °F (-20 to 60 °C). The unit is rated for 10 to 90 % non-condensing humidity and operates at altitudes up to 2000 m.

EMC and immunity compliance

Electrostatic discharge immunity tested to 6 kV contact discharge per IEC 61000-4-2 level 3. The unit also complies with IEC 61000-4-4 (electrical fast transients), FCC Part 15, and UL 61010-2-201. Pollution degree 2 environment — suitable for clean, non-conductive pollution typical of control rooms and light industrial panels.

MPN