Skip to main content
Schneider Electric LA1KN136

Schneider LA1KN136 TeSys K Auxiliary Contact Block, 1NO+3NC,

MPN LA1KN136
Obsolete

Schneider Electric TeSys K LA1KN136 auxiliary contact block, 1NO + 3NC, front mounting, lugs-ring terminals, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LA1KN136 specifications
ParameterValue
Main product or component typeAuxiliary contact block
Voltage690 V AC 25...400 Hz
Insulation voltage ui690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1
IP ratingIP20
Temp storage max80 °C
Temp storage min-50 °C
Temp operating max50 °C
Temp operating min-25 °C
Storage temperature-50...80 °C
Depth35 mm
Width38 mm
Height30 mm
Operating temperature-25...50 °C

Product details

The Schneider LA1KN136 is an auxiliary contact block from the TeSys K range, designed to snap onto the front of a contactor or starter to add signal-feedback or interlock contacts. It carries 1 normally-open and 3 normally-closed instantaneous contacts, wired through lugs-ring terminals. The block is rated for 690 V AC insulation (IEC 60947-5-1) and a conventional free-air thermal current of 10 A at 50 °C, with a making capacity of 110 A at 10 MΩ.

Front-mounting means it clips onto the contactor face, not the side — so it adds depth to the assembly rather than width. The 35 mm depth and 38 mm width keep the stack within a standard DIN-rail enclosure's gutter space. IP20 protection is fine for a closed panel; no washdown rating here.

The 1NO+3NC pole composition is unusual — most auxiliary blocks offer a balanced split (2NO+2NC or 1NO+1NC). This block gives you three NC contacts for safety interlock or status loops where the closed state is the expected running condition. The 10 A thermal current at 50 °C is the continuous carry rating through the contacts; the 110 A making capacity covers the inrush when closing onto a load like a contactor coil or small solenoid.

Environmental limits

Operates between -25 °C and 50 °C, stores from -50 °C to 80 °C. Altitude limit is 2000 m — above that, derate the insulation voltage. Protective treatment is TC conforming to IEC 60068, which covers basic corrosion resistance for normal indoor environments.

MPN
LA1KN136