Schneider LA1LC070E TeSys undervoltage trip, 48 V AC, 0.2 s

MPNLA1LC070E
Obsolete

Schneider Electric TeSys series, LA1LC070E undervoltage trip, 48 V AC 50/60 Hz, 0.2 s time delay, set of 10.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LA1LC070E — Identification
ParameterValue
Product / component typeUndervoltage trip
Product rangeTeSys
LA1LC070E — Other specifications
ParameterValue
Time delay0.2 s
Quantity per setSet of 10
Device short nameLA1LC
Inrush power in8 VA AC
Voltage release typeUndervoltage release
Threshold tripping voltage0.35...0.7 Uc
Coil voltage48 V AC 50/60 Hz
Control circuit voltage limits0.8...1.1 Uc
Hold-in power consumption in4 VA AC

Product details

The LA1LC070E is an undervoltage trip (undervoltage release) from the Schneider TeSys range, designed to drop a contactor or motor starter when the control voltage falls below a set threshold. It operates on a 48 V AC 50/60 Hz control circuit and includes a 0.2 s time delay to ride through brief sags and avoid nuisance tripping. The trip threshold is adjustable between 0.35 and 0.7 times the control circuit voltage (Uc), so on a 48 V line it trips between roughly 17 V and 34 V. The hold-in power draw is 4 VA AC, with an inrush of 8 VA AC at pickup.

The 48 V AC control voltage is specific — this is not a 24 V or 110 V coil. Verify that your control transformer or supply matches 48 V AC at 50 or 60 Hz. The undervoltage release function means the contactor drops out when voltage dips below the threshold, protecting motors from restarting after a brownout. The 0.2 s time delay is short — it will not ride through a typical 0.5 s utility recloser event, but it will ignore brief switching transients. The adjustable threshold lets you set the dropout point to match your system's voltage ride-through requirements. Supplied as a set of 10 units, this is a service-part pack aimed at MRO planners stocking spares for a bank of TeSys contactors on a panel.

Frequently asked questions

What voltage does the LA1LC070E operate on?

It operates on a 48 V AC control circuit at 50/60 Hz, with an operating range of 0.8 to 1.1 times Uc (roughly 38 V to 53 V).

What is the time delay on this undervoltage trip?

The built-in time delay is 0.2 seconds, which helps prevent nuisance tripping on brief voltage sags.

How is the LA1LC070E sourced since it is obsolete?

It is sourced through surplus and broker channels. We locate and quote it against an RFQ — no firm stock is held, but the part can be found for line-down or maintenance needs.

MPN
LA1LC070E