Skip to main content
Schneider Electric LADN029

LADN029 TeSys Deca Auxiliary Contact Block, 2 NC, Faston Ter

MPN LADN029
Obsolete

Schneider Electric TeSys Deca auxiliary contact block, LADN029, 2 NC contacts, Faston terminals, 10 A conventional free air thermal current, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LADN029 specifications
ParameterValue
Protection typeGG fuse 10 A
Main product or component typeAuxiliary contact block
Voltage690 V AC 25...400 Hz
Insulation voltage ui690 V conforming to IEC 60947-5-1 600 V conforming to UL 60947-5-1 600 V conforming to CSA C22.2 No 60947-5-1
Current6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13
IP ratingIP20
Temp storage max80 °C
Temp storage min-60 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-60...80 °C
Depth42 mm
Width26 mm
Height48 mm
Mechanical life cycles30 Mcycles
Operating temperature-5...60 °C

Product details

The LADN029 is a TeSys Deca auxiliary contact block from Schneider Electric, providing 2 NC instantaneous contacts in a front-mount package with Faston terminals. Rated at 10 A conventional free air thermal current (Ith) at 60 °C, it handles 6 A at 120 V AC-15 and 0.55 A at 125 V DC-13 — the AC-15 figure governs solenoid and contactor coil loads, while the DC-13 rating applies to electromagnetic loads with a high inrush. Insulation voltage is 690 V per IEC 60947-5-1, with a making capacity of 140 A AC and 250 A DC per the same standard — enough to handle momentary inrush from a contactor coil without welding the contacts.

The 2 NC configuration is common for safety circuits or feedback loops where the closed state must be verified. IP20 protection means it is suitable for installation inside a control cabinet, not in washdown or outdoor locations. The TH protective treatment per IEC 60068 confirms it can handle humid, tropical environments typical of untreated enclosures. Mechanical durability of 30 million cycles means this block outlasts most contactor bodies it pairs with — the wear limit is usually the main contactor's electrical life, not this auxiliary.

Integration notes

Mounts on the front of a TeSys D or TeSys Deca contactor or reversing starter. Faston terminals accept wire; the 26 mm width matches the contactor footprint, so no extra DIN rail space is consumed. The minimum switching current of 5 mA and minimum voltage of 17 V mean it can reliably switch PLC-level signals, not just power loads — useful for low-energy feedback circuits.

MPN