Skip to main content
Schneider Electric LADN049 — Motor Control Accessories

Schneider LADN049 TeSys Deca Auxiliary Contact Block, 4NC, O

MPNLADN049
Obsolete

Schneider Electric TeSys Deca auxiliary contact block, LADN049, 4NC, front mounting, Faston terminals, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LADN049 — Identification
ParameterValue
Product / component typeAuxiliary contact block
Product rangeTeSys TeSys Deca
LADN049 — Electrical
ParameterValue
Rated operational voltage (Ue)690 V AC 25...400 Hz
Pole / contact composition4 NC
LADN049 — Cable & Connector
ParameterValue
Terminal connection capacityFaston terminals
LADN049 — Mechanical
ParameterValue
Width1.7 in (44 mm)
Height1.9 in (48 mm)
Depth1.7 in (42 mm)
LADN049 — Environmental
ParameterValue
IP protection ratingIP20 conforming to IEC 60529
Operating ambient temperature23...140 °F (-5...60 °C)
Storage ambient temperature-76...176 °F (-60...80 °C)
Operating altitude3000 m
Environmental classNormal environment

Product details

The LADN049 is an auxiliary contact block from the TeSys Deca range, designed for front mounting on TeSys Deca contactors and reversing starters. It provides four normally-closed (4NC) instantaneous contacts, wired via Faston terminals, to signal contactor position or interlock control circuits. Rated operational current is 6 A at 120 V AC-15 (pilot-duty inductive loads), derating to 1.04 A at 690 V AC-15. For DC-13 solenoid loads, it handles 0.55 A at 125 V DC and 0.1 A at 600 V DC. The conventional free-air thermal current (Ith) is 10 A at 60 °C, protected by a 10 A GG fuse. Making capacity is 140 A AC and 250 A DC per IEC 60947-5-1, adequate for momentary inrush on pilot-duty solenoids.

Integration Notes

Mounts on the front of TeSys Deca contactors (e.g., LC1D series) without additional hardware. The IP20 finger-safe enclosure suits panel installation where incidental contact is possible. The block occupies 44 mm width and 42 mm depth on the contactor face. Minimum switching requirements of 5 mA at 17 V ensure reliable dry-circuit signalling to a PLC input without contact wetting.

Frequently asked questions

What is the closest alternative to LADN049?

No official direct replacement has been published by the manufacturer. A functionally similar auxiliary contact block from the current TeSys Deca range (e.g., LADN series with 4NC contacts) may fit the same contactor footprint, but pin compatibility and electrical ratings should be verified against the specific application before substitution.

What are the key electrical ratings of LADN049?

Rated operational current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, and 0.1 A at 600 V DC-13. Conventional free-air thermal current is 10 A at 60 °C. Making capacity is 140 A AC and 250 A DC per IEC 60947-5-1.

MPN
LADN049