Specifications

LADN20R — Identification
ParameterValue
Product / component typeAuxiliary contact block
Product rangeTeSys TeSys Deca
LADN20R — Electrical
ParameterValue
Rated operational voltage (Ue)690 V AC 25...400 Hz
Pole / contact composition2 NO
LADN20R — Cable & Connector
ParameterValue
Terminal connection capacityScrew-clamp terminals 1 cable(s) 1...4 mm²flexible with cable end Screw-clamp terminals 1 cable(s) 1...4 mm²flexible without cable end Screw-clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end Screw-clamp terminals 2 cable(s) 1...4 mm²flexible without cable end Screw-clamp terminals 1 cable(s) 1...4 mm²rigid without cable end Screw-clamp terminals 2 cable(s) 1...4 mm²rigid without cable end
LADN20R — Mechanical
ParameterValue
Width44 mm
Height48 mm
Depth42 mm
ColourDark grey
LADN20R — Environmental
ParameterValue
IP protection ratingIP2X conforming to IEC 60529
Operating ambient temperature-25...60 °C -40...-25 °C with derating 60...70 °C with derating
Storage ambient temperature-60...80 °C
Operating altitude3000 m
Environmental classNormal environment Harsh environment 3S4
LADN20R — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-5-1 GB/T 14048.5 EN 50012 UL 60947-5-1 CSA C22.2 No 60947-5-1 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ

Product details

Overview

The LADN20R is a Schneider TeSys Deca auxiliary contact block, order code LADN20R, providing 2 normally-open contacts rated for 6 A switching current at 690 V insulation voltage. It uses screw-clamp terminals accepting 1 to 4 mm² conductors and mounts to the front of TeSys D, TeSys Deca, and TeSys F contactors and reversing contactors.

As an add-on block, the LADN20R extends the control-circuit I/O of the base contactor without additional wiring to the main power poles. The 2 NO contacts close when the contactor coil energises, providing a dry signal for PLC inputs, status lamps, or interlocking logic. Rated making capacity reaches 140 A AC and 250 A DC per IEC 60947-5-1, with a permissible short-time rating of 100 A for 1 second at 60 °C — figures that cover inrush from pilot devices and small solenoids.

Applications

Auxiliary contact blocks of this class are used across motor control centres, conveyor systems, pump panels, and HVAC equipment to signal contactor state back to a controller or to chain multiple contactors in a sequence. The LADN20R fits panels where only normally-open status feedback is needed — for example, a run indication on a starter or a permissive signal for a downstream device.

The LADN20R is officially discontinued by Schneider. No direct replacement part number has been published. For existing installations, sourcing from surplus or broker channels is the typical route; an RFQ will confirm current availability and lead time. Buyers with active BOMs should evaluate the LADN20A (2 NO + 2 NC) as a functional alternative, noting the additional NC contacts.

MPN
LADN20R