Schneider Electric TeSys Deca auxiliary contact block, LADN226JTQ, 2NO + 2NC, front mounting, lugs-ring terminals, pack of 10.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LADN226JTQ — Identification
ParameterValue
Product / component typeAuxiliary contact block
Product rangeTeSys TeSys Deca
LADN226JTQ — Electrical
ParameterValue
Rated operational voltage (Ue)690 V AC 25...400 Hz
Pole / contact composition2 NO + 2 NC
LADN226JTQ — Cable & Connector
ParameterValue
Terminal connection capacityLugs-ring terminals (external diameter: 8 mm)
LADN226JTQ — Mechanical
ParameterValue
Width44 mm
Height48 mm
Depth42 mm
ColourDark grey
LADN226JTQ — Environmental
ParameterValue
IP protection ratingIP20 conforming to IEC 60529
Operating ambient temperature-5...60 °C
Storage ambient temperature-60...80 °C
Operating altitude3000 m
Environmental classNormal environment

Product details

The LADN226JTQ is a TeSys Deca auxiliary contact block from Schneider Electric, configured with 2 normally-open and 2 normally-closed instantaneous contacts. It mounts on the front of a TeSys Deca contactor or reversing starter, adding control-circuit feedback or interlocking logic. The contacts are rated for 6 A at 120 V AC-15 (inductive solenoid loads) and 0.55 A at 125 V DC-13 (DC solenoid loads), with a conventional free-air thermal current of 10 A at 60 °C.

Schneider has marked the LADN226JTQ as obsolete. If your panel design can accept a parametric equivalent, a current-production TeSys Deca auxiliary block with the same 2NO+2NC contact arrangement and front-mount footprint is the practical substitute; verify the terminal style (lugs-ring vs. screw-clamp) and packing quantity against your stores.

The AC-15 and DC-13 ratings govern inductive load switching: 6 A at 120 V AC covers most 120 V control relays and contactor coils; the 0.55 A at 125 V DC-13 is the figure to check for DC solenoid or brake circuits. Minimum switching capability is 5 mA at 17 V, so the block can handle low-level PLC signals without contact wetting issues. The 1.5 ms non-overlap time between NC and NO contacts during energisation and de-energisation ensures break-before-make in safety interlock or reversing circuits.

Front-mounting on a TeSys Deca contactor or reversing starter — no DIN-rail space consumed. Connections use lugs-ring terminals accepting an 8 mm outer diameter ring; tightening torque is 1.7 N·m with a flat, Philips No 2, or Pozidriv No 2 screwdriver on the M3.5 screw. The block is 44 mm wide, 48 mm high, and 42 mm deep, colour dark grey. Operating temperature range is -5 to 60 °C, storage -60 to 80 °C, with TH protective treatment per IEC 60068 for humid environments. Altitude rating is 3000 m without derating.

Frequently asked questions

What is the closest alternative to LADN226JTQ in the TeSys Deca family?

Schneider does not list an official successor order code. A current-production TeSys Deca auxiliary contact block with the same 2NO+2NC contact arrangement and front-mount footprint is the practical substitute; verify terminal style (lugs-ring vs. screw-clamp) and packing quantity.

What is the depth of LADN226JTQ?

The depth is 42 mm.

What is the range of LADN226JTQ?

It belongs to the TeSys Deca range.

What compliance documentation is available for LADN226JTQ?

The block is rated per IEC 60947-5-1, UL 60947-5-1, and CSA C22.2 No 60947-5-1 for insulation voltage. It carries IP20 protection per IEC 60529 and TH protective treatment per IEC 60068. RoHS and REACH compliance are standard for Schneider TeSys products but are not explicitly listed in this part's record.