Schneider Electric LADN22A — Motor Control Accessories

Schneider LADN22A TeSys Deca Auxiliary Contact Block, 2NO+2N

MPNLADN22A
Active

Schneider Electric TeSys Deca LADN22A auxiliary contact block, 2NO+2NC, front mounting, snap-in terminals, 10 A thermal current, IP20.

$54.06Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LADN22A — Identification
ParameterValue
Product / component typeAuxiliary contact block
Product rangeTeSys TeSys Deca
LADN22A — Electrical
ParameterValue
Rated operational voltage (Ue)690 V AC 25...400 Hz
Pole / contact composition2 NO + 2 NC
LADN22A — Cable & Connector
ParameterValue
Terminal connection capacitysnap-in terminal 1 0.002...0.006 in² (1...4 mm²)flexible with cable end snap-in terminal 1 0.002...0.006 in² (1...4 mm²)flexible without cable end snap-in terminal 2 0.002...0.004 in² (1...2.5 mm²)flexible with cable end snap-in terminal 2 0.002...0.006 in² (1...4 mm²)flexible without cable end snap-in terminal 1 0.002...0.006 in² (1...4 mm²)rigid without cable end snap-in terminal 2 0.002...0.006 in² (1...4 mm²)rigid without cable end
LADN22A — Mechanical
ParameterValue
Width1.7 in (44 mm)
Height1.9 in (48 mm)
Depth1.7 in (42 mm)
LADN22A — Environmental
ParameterValue
IP protection ratingIP20 conforming to IEC 60529
Operating ambient temperature23...140 °F (-5...60 °C)
Storage ambient temperature-76...176 °F (-60...80 °C)
Operating altitude9842.52 ft (3000 m)
Environmental classNormal environment
LADN22A — Approvals
ParameterValue
Conformance standardsEN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN 50012 IEC 60335-1:Clause 30.2 IEC 60335-2-40:Annex JJ

Product details

The Schneider LADN22A is a TeSys Deca auxiliary contact block — 2NO+2NC instantaneous contacts that snap onto the front of a TeSys Deca contactor or reversing starter. The block is IP20 protected, so it lives inside the panel, not on the line side of the enclosure.

The 2NO+2NC contact arrangement gives you two normally-open and two normally-closed auxiliary contacts in one block — enough to handle a feedback loop, a status light, and a PLC input without stacking a second block. The 10 A thermal rating (Ith) is the continuous current the contacts can carry in free air at 60 °C; the operational current (Ie) drops to 6 A at 120 V AC-15 and 0.55 A at 125 V DC-13, which is typical for control-circuit loads like contactor coils and indicator lamps. The minimum switching capability is 5 mA at 17 V, so it will reliably switch low-level PLC inputs without contact wetting issues.

Integration notes

Mounts on the front of a TeSys Deca contactor via snap-in terminals that accept 1 to 4 mm² flexible or rigid wire. The block dimensions are 42 mm deep by 44 mm wide by 48 mm tall — it adds about 42 mm to the depth of the contactor. The block carries EN/IEC 60947-5-1 and UL 60947-5-1 approvals, so it's accepted in both IEC and North American panels.

Frequently asked questions

What are the key ratings for LADN22A?

The block has 2NO+2NC contacts, a conventional free air thermal current of 10 A at 60 °C, rated operational voltage up to 690 V AC, and a minimum switching capability of 5 mA at 17 V.

What compliance standards does LADN22A meet?

It complies with EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, EN 50012, and portions of IEC 60335 for household appliance safety.

What is the physical size of LADN22A?

The block measures 1.7 in (42 mm) deep, 1.7 in (44 mm) wide, and 1.9 in (48 mm) high.

MPN
LADN22A